1206SFF Series, Fuses

Results:
3
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Approval Agency
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Operating Temperature
Response Time
Color
Fuse Type
Mounting Type
Size / Dimension
Package / Case
Voltage Rating - AC
Results remaining3
Applied Filters:
1206SFF
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeVoltage Rating - ACCurrent Rating (Amps)Operating TemperatureApproval AgencyPackage / CaseResponse TimeVoltage Rating - DCSeriesFuse TypeBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
1206SFF600F/32-2
FUSE BOARD MOUNT 6A 32VDC 1206
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
6 A
-55°C ~ 125°C
-
1206 (3216 Metric)
Fast Blow
32 V
1206SFF
Board Mount (Cartridge Style Excluded)
-
1
0.126" L x 0.063" W x 0.043" H (3.20mm x 1.60mm x 1.10mm)
1206SFF700F/32-2
FUSE BOARD MOUNT 7A 24VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
7 A
-55°C ~ 125°C
UL
1206 (3216 Metric)
Fast Blow
24 V
1206SFF
Board Mount (Cartridge Style Excluded)
45A
1.75
0.126" L x 0.063" W x 0.043" H (3.20mm x 1.60mm x 1.10mm)
1206SFF800F/32-2
FUSE BOARD MOUNT 8A 32VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
8 A
-55°C ~ 125°C
UL
1206 (3216 Metric)
Fast Blow
32 V
1206SFF
Board Mount (Cartridge Style Excluded)
45A
2.5
0.126" L x 0.063" W x 0.043" H (3.20mm x 1.60mm x 1.10mm)

Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.