153 Series, Fuses

Results:
12
Manufacturer
Series
Melting I²t
Color
Current Rating (Amps)
Operating Temperature
Breaking Capacity @ Rated Voltage
Size / Dimension
Voltage Rating - AC
Response Time
Approval Agency
Fuse Type
Mounting Type
Voltage Rating - DC
Package / Case
Results remaining12
Applied Filters:
153
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureColorResponse TimeVoltage Rating - DCMounting TypeCurrent Rating (Amps)Approval AgencySeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionVoltage Rating - AC
153.7011.6402
FUSE BF2 M6 32V/1500A DC 400A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Violet
-
32 V
Bolt Mount
400 A
cURus
153
Automotive
Auto Link
1.5kA
964000
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7011.6502
FUSE BF2 M6 32V/1500A DC 500A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Brown
-
32 V
Bolt Mount
500 A
cURus
153
Automotive
Auto Link
1.5kA
-
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7000.6201
FUSE BF1 M6 32V/2000A DC 200A 10
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 125°C
Purple
-
32 V
Bolt Mount
200 A
cURus
153
Automotive
Auto Link
1.5kA
126000
-
-
153.7011.6102
FUSE BF2 M6 32V/2000A DC 100A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Yellow
-
32 V
Bolt Mount
100 A
cURus
153
Automotive
Auto Link
2kA
46800
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7011.6152
FUSE BF2 M6 32V/2000A DC 150A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Orange
-
32 V
Bolt Mount
150 A
cURus
153
Automotive
Auto Link
2kA
113400
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7011.6202
FUSE BF2 M6 32V/2000A DC 200A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Blue
-
32 V
Bolt Mount
200 A
cURus
153
Automotive
Auto Link
2kA
288000
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7011.6252
FUSE BF2 M6 32V/2000A DC 250A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Pink
-
32 V
Bolt Mount
250 A
cURus
153
Automotive
Auto Link
2kA
292500
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7000.6152
FUSE BF1 M6 32V/2000A DC 150A 50
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 125°C
Gray
-
32 V
Bolt Mount
150 A
cURus
153
Automotive
Auto Link
2kA
98000
-
-
153.7011.6122
FUSE BF2 M6 32V/2000A DC 125A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Green
-
32 V
Bolt Mount
125 A
cURus
153
Automotive
Auto Link
2kA
118100
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7011.6172
FUSE BF2 M6 32V/2000A DC 175A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
White
-
32 V
Bolt Mount
175 A
cURus
153
Automotive
Auto Link
2kA
154400
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7011.6222
FUSE BF2 M6 32V/2000A DC 225A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Tan
-
32 V
Bolt Mount
225 A
cURus
153
Automotive
Auto Link
2kA
236000
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-
153.7011.6302
FUSE BF2 M6 32V/2000A DC 300A 20
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Gray
-
32 V
Bolt Mount
300 A
cURus
153
Automotive
Auto Link
2kA
486000
1.142" L x 0.740" W x 0.382" H (29.00mm x 18.80mm x 9.70mm)
-

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.