ADC Series, Fuses

Results:
10
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Mounting Type
Size / Dimension
Package / Case
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Voltage Rating - AC
Results remaining10
Applied Filters:
ADC
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorOperating TemperatureResponse TimeVoltage Rating - ACVoltage Rating - DCCurrent Rating (Amps)Approval AgencySeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionMounting Type
BK-ADC-25-R
FUSE 500V 3AB CARTRIDGE 25A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
25 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
30kA AC, 20kA DC
125
0.252" Dia x 1.252" L (6.40mm x 31.80mm)
Requires Holder
BK-ADC-15-R
FUSE 500V 3AB CARTRIDGE 15A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
15 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
30kA AC, 20kA DC
50
0.252" Dia x 1.252" L (6.40mm x 31.80mm)
Requires Holder
BK-ADC-20-R
FUSE 500V 3AB CARTRIDGE 20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
20 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
30kA AC, 20kA DC
88
0.252" Dia x 1.252" L (6.40mm x 31.80mm)
Requires Holder
BK-ADC-V2-12-R
FUSE 500V 3AB CART AXIAL 12A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
12 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
30kA AC, 20kA DC
120
0.268" Dia x 1.291" L (6.81mm x 32.79mm)
Through Hole
BK-ADC-V2-20-R
FUSE 500V 3AB CART AXIAL 20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
20 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
30kA AC, 20kA DC
88
0.268" Dia x 1.291" L (6.81mm x 32.79mm)
Through Hole
BK-ADC-30-R
FUSE 500V 3AB CARTRIDGE 30A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
30 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
30kA AC, 20kA DC
270
0.252" Dia x 1.252" L (6.40mm x 31.80mm)
Requires Holder
BK-ADC-12-R
FUSE 500V 3AB CARTRIDGE 12A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
12 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
30kA AC, 20kA DC
120
0.252" Dia x 1.252" L (6.40mm x 31.80mm)
Requires Holder
BK-ADC-V2-30-R
FUSE 500V 3AB CART AXIAL 30A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
30 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
30kA AC, 20kA DC
270
0.268" Dia x 1.291" L (6.81mm x 32.79mm)
Through Hole
BK-ADC-V2-25-R
FUSE 500V 3AB CART AXIAL 25A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
25 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
30kA AC, 20kA DC
125
0.268" Dia x 1.291" L (6.81mm x 32.79mm)
Through Hole
BK-ADC-V2-15-R
FUSE 500V 3AB CART AXIAL 15A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-50°C ~ 125°C
Fast Blow
500 V
500 V
15 A
cURus, UL
ADC
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
30kA AC, 20kA DC
50
0.268" Dia x 1.291" L (6.81mm x 32.79mm)
Through Hole

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.