Military, MIL-PRF-M15305, MS75083 Series, Fixed Inductors

Results:
9
Manufacturer
Series
Current Rating (Amps)
DC Resistance (DCR)
Inductance
Frequency - Self Resonant
Q @ Freq
Operating Temperature
Current - Saturation (Isat)
Inductance Frequency - Test
Height - Seated (Max)
Tolerance
Shielding
Mounting Type
Size / Dimension
Supplier Device Package
Ratings
Type
Package / Case
Features
Material - Core
Results remaining9
Applied Filters:
Military, MIL-PRF-M15305, MS75083
Select
ImageProduct DetailPriceAvailabilityECAD ModelTypeSupplier Device PackageFeaturesMounting TypeHeight - Seated (Max)ShieldingToleranceOperating TemperatureRatingsCurrent - Saturation (Isat)Package / CaseMaterial - CoreSeriesInductanceCurrent Rating (Amps)DC Resistance (DCR)Q @ FreqFrequency - Self ResonantInductance Frequency - TestSize / Dimension
1025-18K
API Delevan Inc.
FIXED IND 820NH 420MA 850MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
820 nH
420 mA
850mOhm Max
28 @ 25MHz
250MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-02K
API Delevan Inc.
FIXED IND 180NH 1.12A 120MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
180 nH
1.12 A
120mOhm Max
35 @ 25MHz
550MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-14K
API Delevan Inc.
FIXED IND 560NH 550MA 500MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
560 nH
550 mA
500mOhm Max
30 @ 25MHz
300MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-06K
API Delevan Inc.
FIXED IND 270NH 975MA 160MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
270 nH
975 mA
160mOhm Max
33 @ 25MHz
430MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-94K
API Delevan Inc.
FIXED IND 100NH 1.38A 80 MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
100 nH
1.38 A
80mOhm Max
40 @ 25MHz
680MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-12K
API Delevan Inc.
FIXED IND 470NH 660MA 350MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
470 nH
660 mA
350mOhm Max
30 @ 25MHz
330MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-20K
API Delevan Inc.
FIXED IND 1UH 390MA 1 OHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
1 µH
390 mA
1Ohm Max
25 @ 25MHz
230MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-00K
API Delevan Inc.
FIXED IND 150NH 1.23A 100MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
150 nH
1.23 A
100mOhm Max
38 @ 25MHz
600MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)
1025-08K
API Delevan Inc.
FIXED IND 330NH 830MA 220MOHM TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
-
Unshielded
±10%
-55°C ~ 125°C
-
-
Axial
Phenolic
Military, MIL-PRF-M15305, MS75083
330 nH
830 mA
220mOhm Max
30 @ 25MHz
410MHz
25 MHz
0.095" Dia x 0.250" L (2.41mm x 6.35mm)

Fixed Inductors

Inductors, also known as coils, chokes, or reactors, are fundamental passive electrical components with two terminals that store energy in a magnetic field when an electric current flows through them. When the current changes, the magnetic field induces a voltage in the conductor. The induced voltage has a polarity that opposes the change in current that generated it, creating a self-inductance effect. The unit of measurement for inductance is the Henry (H), named after the American physicist Joseph Henry. Inductors are present in various forms and sizes, ranging from microhenries (μH) to millihenries (mH) and even higher. In practical applications, inductors can be used to filter out unwanted high-frequency signals and to store and release energy in DC-DC converters. Inductors can also be used in conjunction with capacitors to create resonant circuits for filtering specific frequencies. Inductors come in different mounting options, including surface mount technology (SMT), through-hole, and chassis mounting. Surface mount inductors are ideal for compact designs, while through-hole inductors provide robustness and ease of assembly. Chassis-mounted inductors offer a more rugged design for industrial and heavy-duty applications. In summary, inductors are essential components in electronic circuits, providing energy storage, signal filtering, and frequency selection capabilities. With a wide range of mounting options and applications, these fundamental passive components play a vital role in modern electronics.