0AMA Series, Electrical, Specialty Fuses

Results:
9
Manufacturer
Series
Current Rating (Amps)
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Features
Class
Results remaining9
Applied Filters:
0AMA
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureFeaturesClassResponse TimeCurrent Rating (Amps)Approval AgencyFuse TypePackage / CaseApplicationsBreaking Capacity @ Rated VoltageMounting TypeVoltage Rating - ACVoltage Rating - DCSeriesSize / Dimension
0AMA-0050-TD
FUSE HAZARD LOCATION 250V 50MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
50mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0200-TD
FUSE HAZARD LOCATION 250V 200MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
200mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0250-TD
FUSE HAZARD LOCATION 250V 250MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
250mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0125-TD
FUSE HAZARD LOCATION 250V 125MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
125mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0040-TD
FUSE HAZARD LOCATION 250V 40MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
40mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0160-TD
FUSE HAZARD LOCATION 250V 160MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
160mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0080-TD
FUSE HAZARD LOCATION 250V 80MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
80mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0063-TD
FUSE HAZARD LOCATION 250V 63MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
63mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)
0AMA-0100-TD
FUSE HAZARD LOCATION 250V 100MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-55°C ~ 125°C
Intrinsically Safe
-
Fast Blow
100mA
cURus
Cartridge
Cartridge, Non-Standard
Hazardous Locations
4kA
Requires Holder
250 VAC
250 VDC
0AMA
0.118" Dia x 0.343" L (3.00mm x 8.70mm)

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.