LNRK600.X
FUSE CRTRDGE 600A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® LLNRK
600A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.843" Dia x 10.374" L (72.20mm x 263.50mm)
Requires Holder
125 VDC
250 VAC
LNRK450.X
FUSE CRTRDGE 450A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® LLNRK
450A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.843" Dia x 10.374" L (72.20mm x 263.50mm)
Requires Holder
125 VDC
250 VAC
LNRK003.T
FUSE CARTRIDGE 3A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
3A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK03.2T
FUSE CRTRDGE 3.2A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
3.2A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK002.T
FUSE CARTRIDGE 2A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
2A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK008.T
FUSE CARTRIDGE 8A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
8A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK012.T
FUSE CARTRIDGE 12A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
12A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK006.T
FUSE CARTRIDGE 6A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
6A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK004.T
FUSE CARTRIDGE 4A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
4A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK005.T
FUSE CARTRIDGE 5A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
5A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK010.T
FUSE CARTRIDGE 10A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
10A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK1.12T
FUSE CRTRDGE 1.12A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
1.12A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK01.8T
FUSE CRTRDGE 1.8A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
1.8A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK2.25T
FUSE CRTRDGE 2.25A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
2.25A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK.100T
FUSE CRTRDGE 100MA 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
100mA
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK.400T
FUSE CRTRDGE 400MA 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
400mA
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK.150T
FUSE CRTRDGE 150MA 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
150mA
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK01.4T
FUSE CRTRDGE 1.4A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
1.4A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK.200T
FUSE CRTRDGE 200MA 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
200mA
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC
LNRK02.5T
FUSE CRTRDGE 2.5A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® LLNRK
2.5A
Electrical, Industrial
RK1
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.563" Dia x 2.000" L (14.30mm x 50.80mm)
Requires Holder
125 VDC
250 VAC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.