ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureApproval AgencyResponse TimeCurrent Rating (Amps)Fuse TypePackage / CaseSeriesApplicationsClassBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeVoltage Rating - ACVoltage Rating - DC
0JTD040.T
FUSE CARTRIDGE 40A 600VAC/300VDC
1+
¥828.0000
5+
¥782.0000
10+
¥736.0000
Quantity
469 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
40A
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.063" Dia x 2.374" L (27.00mm x 60.30mm)
Requires Holder
600 VAC
300 VDC
0JTD080.V
FUSE CARTRIDGE 80A 600VAC/300VDC
1+
¥900.0000
5+
¥850.0000
10+
¥800.0000
Quantity
10 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
80A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.126" Dia x 2.626" L (28.60mm x 66.70mm)
Requires Holder
600 VAC
300 VDC
0JTD125.X
FUSE CRTRDGE 125A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
125A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.500" Dia x 3.000" L (38.10mm x 76.20mm)
Requires Holder
600 VAC
500 VDC
0JTD03.2T
FUSE CRTRDGE 3.2A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
3.2A
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
0.811" Dia x 2.252" L (20.60mm x 57.20mm)
Requires Holder
600 VAC
300 VDC
0JTD070.V
FUSE CARTRIDGE 70A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
70A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.126" Dia x 2.626" L (28.60mm x 66.70mm)
Requires Holder
600 VAC
300 VDC
0JTD450.X
FUSE CRTRDGE 450A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
450A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
2.500" Dia x 3.752" L (63.50mm x 95.30mm)
Requires Holder
600 VAC
500 VDC
0JTD500.X
FUSE CRTRDGE 500A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
500A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
2.500" Dia x 3.752" L (63.50mm x 95.30mm)
Requires Holder
600 VAC
500 VDC
0JTD600.X
FUSE CRTRDGE 600A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
600A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
2.500" Dia x 3.752" L (63.50mm x 95.30mm)
Requires Holder
600 VAC
500 VDC
0JTD015.T
FUSE CARTRIDGE 15A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
15A
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
0.811" Dia x 2.252" L (20.60mm x 57.20mm)
Requires Holder
600 VAC
300 VDC
0JTD030.T
FUSE CARTRIDGE 30A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
30A
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
0.811" Dia x 2.252" L (20.60mm x 57.20mm)
Requires Holder
600 VAC
300 VDC
0JTD010.T
FUSE CARTRIDGE 10A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
10A
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
0.811" Dia x 2.252" L (20.60mm x 57.20mm)
Requires Holder
600 VAC
300 VDC
0JTD020.T
FUSE CARTRIDGE 20A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
20A
Cartridge
Cartridge, Non-Standard
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
0.811" Dia x 2.252" L (20.60mm x 57.20mm)
Requires Holder
600 VAC
300 VDC
0JTD150.X
FUSE CRTRDGE 150A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
150A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.500" Dia x 3.000" L (38.10mm x 76.20mm)
Requires Holder
600 VAC
500 VDC
0JTD110.X
FUSE CRTRDGE 110A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
110A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.500" Dia x 3.000" L (38.10mm x 76.20mm)
Requires Holder
600 VAC
500 VDC
0JTD175.X
FUSE CRTRDGE 175A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
175A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.500" Dia x 3.000" L (38.10mm x 76.20mm)
Requires Holder
600 VAC
500 VDC
0JTD200.X
FUSE CRTRDGE 200A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
200A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
1.500" Dia x 3.000" L (38.10mm x 76.20mm)
Requires Holder
600 VAC
500 VDC
0JTD300.X
FUSE CRTRDGE 300A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
300A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
2.000" Dia x 3.374" L (50.80mm x 85.70mm)
Requires Holder
600 VAC
500 VDC
0JTD250.X
FUSE CRTRDGE 250A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
250A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
2.000" Dia x 3.374" L (50.80mm x 85.70mm)
Requires Holder
600 VAC
500 VDC
0JTD225.X
FUSE CRTRDGE 225A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
225A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
2.000" Dia x 3.374" L (50.80mm x 85.70mm)
Requires Holder
600 VAC
500 VDC
0JTD350.X
FUSE CRTRDGE 350A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
350A
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® JTD
Transformer Protection
J
200kA AC, 20kA DC
2.000" Dia x 3.374" L (50.80mm x 85.70mm)
Requires Holder
600 VAC
500 VDC

Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.