POWR-GARD®, POWR-PRO® IDSR Series, Electrical, Specialty Fuses

Results:
63
Manufacturer
Series
Current Rating (Amps)
Size / Dimension
Package / Case
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Voltage Rating - DC
Voltage Rating - AC
Class
Features
Results remaining63
Applied Filters:
POWR-GARD®, POWR-PRO® IDSR
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureCurrent Rating (Amps)Approval AgencyResponse TimeFuse TypePackage / CaseSeriesApplicationsFeaturesClassBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeVoltage Rating - ACVoltage Rating - DC
IDSR001.T
FUSE CARTRIDGE 1A 600VAC/VDC CYL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
1A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR.100T
FUSE CARTRIDGE 100MA 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
100mA
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR2.25T
FUSE CARTRIDGE 2.25A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
2.25A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR04.5T
FUSE CARTRIDGE 4.5A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
4.5A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR02.5T
FUSE CARTRIDGE 2.5A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
2.5A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR05.6T
FUSE CARTRIDGE 5.6A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
5.6A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR.600T
FUSE CARTRIDGE 600MA 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
600mA
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR.500T
FUSE CARTRIDGE 500MA 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
500mA
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR01.4T
FUSE CARTRIDGE 1.4A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
1.4A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR1.12T
FUSE CARTRIDGE 1.12A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
1.12A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR.800T
FUSE CARTRIDGE 800MA 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
800mA
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
600 VDC
IDSR100.V
FUSE CARTRIDGE 100A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
100A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.311" Dia x 5.748" L (33.30mm x 146.00mm)
Requires Holder
600 VAC
600 VDC
IDSR080.V
FUSE CARTRIDGE 80A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
80A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.311" Dia x 5.748" L (33.30mm x 146.00mm)
Requires Holder
600 VAC
600 VDC
IDSR070.V
FUSE CARTRIDGE 70A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
70A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.311" Dia x 5.748" L (33.30mm x 146.00mm)
Requires Holder
600 VAC
600 VDC
IDSR090.V
FUSE CARTRIDGE 90A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
90A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.311" Dia x 5.748" L (33.30mm x 146.00mm)
Requires Holder
600 VAC
600 VDC
IDSR035.T
FUSE CARTRIDGE 35A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
35A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.063" Dia x 5.500" L (27.00mm x 139.70mm)
Requires Holder
600 VAC
600 VDC
IDSR050.T
FUSE CARTRIDGE 50A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
50A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.063" Dia x 5.500" L (27.00mm x 139.70mm)
Requires Holder
600 VAC
600 VDC
IDSR040.T
FUSE CARTRIDGE 40A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
40A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.063" Dia x 5.500" L (27.00mm x 139.70mm)
Requires Holder
600 VAC
600 VDC
IDSR060.T
FUSE CARTRIDGE 60A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
60A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Alarm Indicating
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
1.063" Dia x 5.500" L (27.00mm x 139.70mm)
Requires Holder
600 VAC
600 VDC
IDSR300.X
FUSE CARTRIDGE 300A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
300A
CE, CSA, UL
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD®, POWR-PRO® IDSR
Electrical, Industrial
Indicating
RK5
200kA AC, 20kA DC
2.594" Dia x 7.626" L (65.90mm x 193.70mm)
Requires Holder
600 VAC
600 VDC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.