POWR-GARD® NLS Series, Electrical, Specialty Fuses

Results:
36
Manufacturer
Series
Current Rating (Amps)
Size / Dimension
Voltage Rating - DC
Breaking Capacity @ Rated Voltage
Package / Case
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Mounting Type
Voltage Rating - AC
Class
Features
Results remaining36
Applied Filters:
POWR-GARD® NLS
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureApproval AgencyResponse TimeCurrent Rating (Amps)Fuse TypePackage / CaseBreaking Capacity @ Rated VoltageSeriesApplicationsClassSize / DimensionMounting TypeVoltage Rating - ACVoltage Rating - DC
0NLS070.V
FUSE CARTRIDGE 70A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
70A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.311" Dia x 5.874" L (33.30mm x 149.20mm)
Requires Holder
600 VAC
600 VDC
0NLS080.V
FUSE CARTRIDGE 80A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
80A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.311" Dia x 5.874" L (33.30mm x 149.20mm)
Requires Holder
600 VAC
600 VDC
0NLS090.V
FUSE CARTRIDGE 90A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
90A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.311" Dia x 5.874" L (33.30mm x 149.20mm)
Requires Holder
600 VAC
600 VDC
0NLS030.T
FUSE CARTRIDGE 30A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
30A
Cartridge
Cartridge, Non-Standard
50kA AC, 20kA DC
POWR-GARD® NLS
Electrical, Industrial
K5
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
500 VDC
0NLS025.T
FUSE CARTRIDGE 25A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
25A
Cartridge
Cartridge, Non-Standard
50kA AC, 20kA DC
POWR-GARD® NLS
Electrical, Industrial
K5
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
500 VDC
0NLS175.X
FUSE CARTRIDGE 175A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
175A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.843" Dia x 6.878" L (46.80mm x 174.70mm)
Requires Holder
600 VAC
600 VDC
0NLS150.X
FUSE CARTRIDGE 150A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
150A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.843" Dia x 6.878" L (46.80mm x 174.70mm)
Requires Holder
600 VAC
600 VDC
0NLS110.X
FUSE CARTRIDGE 110A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
110A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.843" Dia x 6.878" L (46.80mm x 174.70mm)
Requires Holder
600 VAC
600 VDC
0NLS125.X
FUSE CARTRIDGE 125A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
125A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.843" Dia x 6.878" L (46.80mm x 174.70mm)
Requires Holder
600 VAC
600 VDC
0NLS100.V
FUSE CARTRIDGE 100A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
100A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.311" Dia x 5.874" L (33.30mm x 149.20mm)
Requires Holder
600 VAC
600 VDC
0NLS200.X
FUSE CARTRIDGE 200A 600VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
200A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
1.843" Dia x 6.878" L (46.80mm x 174.70mm)
Requires Holder
600 VAC
600 VDC
0NLS250.X
FUSE CRTRDGE 250A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
250A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
2.594" Dia x 7.878" L (65.90mm x 200.10mm)
Requires Holder
600 VAC
500 VDC
0NLS300.X
FUSE CRTRDGE 300A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
300A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
2.594" Dia x 7.878" L (65.90mm x 200.10mm)
Requires Holder
600 VAC
500 VDC
0NLS350.X
FUSE CRTRDGE 350A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
350A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
2.594" Dia x 7.878" L (65.90mm x 200.10mm)
Requires Holder
600 VAC
500 VDC
0NLS400.X
FUSE CRTRDGE 400A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
400A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
2.594" Dia x 7.878" L (65.90mm x 200.10mm)
Requires Holder
600 VAC
500 VDC
0NLS225.X
FUSE CRTRDGE 225A 600VAC/500VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
225A
Cartridge
Cylindrical, Blade Terminals
50kA
POWR-GARD® NLS
Electrical, Industrial
K5
2.594" Dia x 7.878" L (65.90mm x 200.10mm)
Requires Holder
600 VAC
500 VDC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.