POWR-GARD® KLKR Series, Electrical, Specialty Fuses

Results:
50
Manufacturer
Series
Current Rating (Amps)
Applications
Size / Dimension
Operating Temperature
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Class
Features
Results remaining50
Applied Filters:
POWR-GARD® KLKR
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureApproval AgencyResponse TimeFuse TypePackage / CaseSize / DimensionSeriesCurrent Rating (Amps)ApplicationsClassBreaking Capacity @ Rated VoltageMounting TypeVoltage Rating - ACVoltage Rating - DC
KLKR.300T
FUSE CRTRDGE 300MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
300mA
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR009.T
FUSE CARTRIDGE 9A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
9A
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR005.TS
FUSE CARTRIDGE 5A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
5A
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR010.TS
FUSE CARTRIDGE 10A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
10A
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR002.T
FUSE CARTRIDGE 2A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
2A
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR.200TS
FUSE CRTRDGE 200MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.409" Dia x 1.500" L (10.40mm x 38.10mm)
POWR-GARD® KLKR
200mA
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR.300TS
FUSE CRTRDGE 300MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.409" Dia x 1.500" L (10.40mm x 38.10mm)
POWR-GARD® KLKR
300mA
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR.500TS
FUSE CRTRDGE 500MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.409" Dia x 1.500" L (10.40mm x 38.10mm)
POWR-GARD® KLKR
500mA
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR006.TS
FUSE CARTRIDGE 6A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
6A
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR012.TS
FUSE CARTRIDGE 12A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
12A
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR020.TS
FUSE CARTRIDGE 20A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
20A
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR.100T
FUSE CRTRDGE 100MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
100mA
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR.250TS
FUSE CRTRDGE 250MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.409" Dia x 1.500" L (10.40mm x 38.10mm)
POWR-GARD® KLKR
250mA
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR025.TS
FUSE CARTRIDGE 25A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
25A
Motor Protection
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR.200T
FUSE CRTRDGE 200MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
200mA
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR007.T
FUSE CARTRIDGE 7A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
7A
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR004.T
FUSE CARTRIDGE 4A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
4A
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR02.5T
FUSE CRTRDGE 2.5A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
2.5A
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR03.5T
FUSE CRTRDGE 3.5A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
3.5A
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC
KLKR01.5T
FUSE CRTRDGE 1.5A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Fast Blow
Cartridge
5AG, 10mm x 38mm (Midget)
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
POWR-GARD® KLKR
1.5A
Electrical, Industrial
CC
200kA AC, 20kA DC
Requires Holder
600 VAC
300 VDC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.