Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureResponse TimeFuse TypePackage / CaseSeriesCurrent Rating (Amps)ApplicationsClassApproval AgencyBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeVoltage Rating - ACVoltage Rating - DC
FLSR03.2T
FUSE CRTRDGE 3.2A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
3.2A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR400.X
FUSE CRTRDGE 400A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLSR
400A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.594" Dia x 11.626" L (65.90mm x 295.30mm)
Requires Holder
600 VAC
300 VDC
FLSR200.X
FUSE CRTRDGE 200A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLSR
200A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.843" Dia x 9.626" L (46.80mm x 244.50mm)
Requires Holder
600 VAC
300 VDC
FLSR100.V
FUSE CRTRDGE 100A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLSR
100A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.311" Dia x 7.874" L (33.30mm x 200.00mm)
Requires Holder
600 VAC
300 VDC
FLSR002.T
FUSE CARTRIDGE 2A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
2A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR050.T
FUSE CARTRIDGE 50A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
50A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.063" Dia x 5.500" L (27.00mm x 139.70mm)
Requires Holder
600 VAC
300 VDC
FLSR02.8T
FUSE CRTRDGE 2.8A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
2.8A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR007.T
FUSE CARTRIDGE 7A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
7A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR03.5T
FUSE CRTRDGE 3.5A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
3.5A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR009.T
FUSE CARTRIDGE 9A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
9A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR1.25T
FUSE CRTRDGE 1.5A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
1.5A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR005.T
FUSE CARTRIDGE 5A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
5A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR008.T
FUSE CARTRIDGE 8A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
8A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR012.T
FUSE CARTRIDGE 12A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
12A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR.300T
FUSE CRTRDGE 300MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
300mA
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR.150T
FUSE CRTRDGE 150MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
150mA
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR.200T
FUSE CRTRDGE 200MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
200mA
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR.250T
FUSE CRTRDGE 250MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
250mA
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR.100T
FUSE CRTRDGE 100MA 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
100mA
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
FLSR2.25T
FUSE CRTRDGE 2.25A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLSR
2.25A
Electrical, Industrial
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 5.000" L (20.60mm x 127.00mm)
Requires Holder
600 VAC
300 VDC

Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.