POWR-GARD® FLNR_ID Series, Electrical, Specialty Fuses

Results:
22
Manufacturer
Series
Current Rating (Amps)
Size / Dimension
Package / Case
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Voltage Rating - DC
Voltage Rating - AC
Class
Features
Results remaining22
Applied Filters:
POWR-GARD® FLNR_ID
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureResponse TimeFuse TypePackage / CaseSeriesCurrent Rating (Amps)ApplicationsFeaturesClassApproval AgencyBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeVoltage Rating - DCVoltage Rating - AC
FLNR600.XXID
FUSE CRTRDGE 600A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
600A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.594" Dia x 10.374" L (65.90mm x 263.50mm)
Requires Holder
125 VDC
250 VAC
FLNR070.VXID
FUSE CARTRIDGE 70A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
70A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.063" Dia x 5.874" L (27.00mm x 149.20mm)
Requires Holder
125 VDC
250 VAC
FLNR110.XXID
FUSE CRTRDGE 110A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
110A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.594" Dia x 7.126" L (40.50mm x 181.00mm)
Requires Holder
125 VDC
250 VAC
FLNR150.XXID
FUSE CRTRDGE 150A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
150A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.594" Dia x 7.126" L (40.50mm x 181.00mm)
Requires Holder
125 VDC
250 VAC
FLNR080.VXID
FUSE CARTRIDGE 80A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
80A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.063" Dia x 5.874" L (27.00mm x 149.20mm)
Requires Holder
125 VDC
250 VAC
FLNR040.TXID
FUSE CARTRIDGE 40A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLNR_ID
40A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 3.000" L (20.60mm x 76.20mm)
Requires Holder
125 VDC
250 VAC
FLNR050.TXID
FUSE CARTRIDGE 50A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLNR_ID
50A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 3.000" L (20.60mm x 76.20mm)
Requires Holder
125 VDC
250 VAC
FLNR045.TXID
FUSE CARTRIDGE 45A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLNR_ID
45A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 3.000" L (20.60mm x 76.20mm)
Requires Holder
125 VDC
250 VAC
FLNR090.VXID
FUSE CARTRIDGE 90A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
90A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.063" Dia x 5.874" L (27.00mm x 149.20mm)
Requires Holder
125 VDC
250 VAC
FLNR250.XXID
FUSE CRTRDGE 250A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
250A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.094" Dia x 8.626" L (53.19mm x 219.10mm)
Requires Holder
125 VDC
250 VAC
FLNR225.XXID
FUSE CRTRDGE 225A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
225A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.094" Dia x 8.626" L (53.19mm x 219.10mm)
Requires Holder
125 VDC
250 VAC
FLNR350.XXID
FUSE CRTRDGE 350A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
350A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.094" Dia x 8.626" L (53.19mm x 219.10mm)
Requires Holder
125 VDC
250 VAC
FLNR500.XXID
FUSE CRTRDGE 500A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
500A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.594" Dia x 10.374" L (65.90mm x 263.50mm)
Requires Holder
125 VDC
250 VAC
FLNR450.XXID
FUSE CRTRDGE 450A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
450A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.594" Dia x 10.374" L (65.90mm x 263.50mm)
Requires Holder
125 VDC
250 VAC
FLNR300.XXID
FUSE CRTRDGE 300A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
300A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
2.094" Dia x 8.626" L (53.19mm x 219.10mm)
Requires Holder
125 VDC
250 VAC
FLNR060.TXID
FUSE CARTRIDGE 60A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cartridge, Non-Standard
POWR-GARD® FLNR_ID
60A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
0.811" Dia x 3.000" L (20.60mm x 76.20mm)
Requires Holder
125 VDC
250 VAC
FLNR175.XXID
FUSE CRTRDGE 175A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
175A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.594" Dia x 7.126" L (40.50mm x 181.00mm)
Requires Holder
125 VDC
250 VAC
FLNR125.XXID
FUSE CRTRDGE 125A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
125A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.594" Dia x 7.126" L (40.50mm x 181.00mm)
Requires Holder
125 VDC
250 VAC
FLNR100.VXID
FUSE CRTRDGE 100A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
100A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.063" Dia x 5.874" L (27.00mm x 149.20mm)
Requires Holder
125 VDC
250 VAC
FLNR200.XXID
FUSE CRTRDGE 300A 250VAC/125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Slow Blow
Cartridge
Cylindrical, Blade Terminals
POWR-GARD® FLNR_ID
300A
Electrical, Industrial
Indicating
RK5
CE, CSA, QPL, UL
200kA AC, 20kA DC
1.594" Dia x 7.126" L (40.50mm x 181.00mm)
Requires Holder
125 VDC
250 VAC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.