POWR-GARD® 70 Series, Electrical, Specialty Fuses

Results:
15
Manufacturer
Series
Current Rating (Amps)
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Features
Class
Results remaining15
Applied Filters:
POWR-GARD® 70
Select
ImageProduct DetailPriceAvailabilityECAD ModelSize / DimensionOperating TemperatureApproval AgencyMounting TypeResponse TimeClassVoltage Rating - ACFuse TypeVoltage Rating - DCPackage / CaseBreaking Capacity @ Rated VoltageSeriesCurrent Rating (Amps)ApplicationsFeatures
70S00000Z
FUSE CRTRDGE 350MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
350mA
Telecom
Indicating
70J00000Z
FUSE CRTRDGE 3.5A 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
3.5A
Telecom
Indicating
70N00000Z
FUSE CARTRIDGE 10A 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
10A
Telecom
Indicating
70A00000Z
FUSE CRTRDGE 1.33A 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
1.33A
Telecom
Indicating
70X00000Z
FUSE CRTRDGE 200MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
200mA
Telecom
Indicating
70K00000Z
FUSE CRTRDGE 250MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
250mA
Telecom
Indicating
70R00000Z
FUSE CRTRDGE 150MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
150mA
Telecom
Indicating
70D00000Z
FUSE CARTRIDGE 5A 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
5A
Telecom
Indicating
70M00000Z
FUSE CARTRIDGE 8A 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
8A
Telecom
Indicating
70H00000Z
FUSE CRTRDGE 750MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
750mA
Telecom
Indicating
70F00000Z
FUSE CRTRDGE 250MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
250mA
Telecom
Indicating
70E00000Z
FUSE CRTRDGE 180MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
180mA
Telecom
Indicating
70P00000Z
FUSE CRTRDGE 100MA 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
100mA
Telecom
Indicating
70B00000Z
FUSE CARTRIDGE 2A 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
2A
Telecom
Indicating
70C00000Z
FUSE CARTRIDGE 3A 125VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Holder
-
-
125 V
Cartridge
300 V
Cylindrical, Alarm Indicating
1kA
POWR-GARD® 70
3A
Telecom
Indicating

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.