ImageProduct DetailPriceAvailabilityECAD ModelVoltage Rating - DCFeaturesOperating TemperatureResponse TimePackage / CaseBreaking Capacity @ Rated VoltageSeriesFuse TypeCurrent Rating (Amps)ApplicationsClassApproval AgencySize / DimensionMounting TypeVoltage Rating - AC
125NH00GL
FUSE SQUARE 125A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
Rectangular, Blade
-
NH00
Square
125A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
32NH00GR-6
FUSE SQUARE 32A 660VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Fast Blow
Rectangular, Blade
-
NH00
Square
32A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
660 VAC
20NH00GL
FUSE SQUARE 20A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
20A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
50NH00GL
FUSE NHC00 3 50A 500V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
50A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
80NH00GL
FUSE NHC00 80A 500V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
80A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
32NH00GL-6
FUSE SQUARE 32A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
32A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
32NH00AM-6
FUSE SQUARE 32A 660VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Fast Blow
Rectangular, Blade
-
NH00
Square
32A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
660 VAC
25NH00GL-6
FUSE SQUARE 25A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
25A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
2NH00GL
FUSE SQUARE 2A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
2A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
2NH00AM
FUSE SQUARE 2A RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Fast Blow
Rectangular, Blade
-
NH00
Square
2A
-
NH
VDE
-
Requires Holder
-
20NH00GL-6
FUSE SQUARE 20A 660VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
20A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
660 VAC
20NH00GR-6
FUSE SQUARE 20A 660VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Fast Blow
Rectangular, Blade
-
NH00
Square
20A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
660 VAC
40NH00GR-6
FUSE SQUARE 40A 660VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Fast Blow
Rectangular, Blade
-
NH00
Square
40A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
660 VAC
160NH00GL
FUSE SQUARE 160A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
160A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
25NH00GL
FUSE SQUARE 25A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
25A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
6NH00GL
FUSE NH00GL 6A500V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
6A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
63NH00GL
FUSE NH00 3 63A500VGL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
63A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
2NH00AM-6
FUSE SQUARE 2A 660VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Fast Blow
Rectangular, Blade
-
NH00
Square
2A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
660 VAC
2NH00GL-6
FUSE SQUARE 2A 500VAC RECT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
2A
-
NH
VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC
4NH00GL
FUSE NH00G 4A 500V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
Rectangular, Blade
-
NH00
Square
4A
Electrical, Industrial
G
IEC, VDE
2.047" L x 1.673" W x 1.102" H (52.00mm x 42.50mm x 28.00mm)
Requires Holder
500 VAC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.