Low-Peak™ LPS Series, Electrical, Specialty Fuses

Results:
10
Manufacturer
Series
Current Rating (Amps)
Size / Dimension
Mounting Type
Package / Case
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Voltage Rating - AC
Class
Features
Results remaining10
Applied Filters:
Low-Peak™ LPS
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureApproval AgencyResponse TimeCurrent Rating (Amps)Fuse TypePackage / CaseSeriesApplicationsClassBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeVoltage Rating - ACVoltage Rating - DC
LPS-RK-60SP
FUSE CARTRIDGE 60A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
60A
Cartridge
Cartridge, Non-Standard
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
1.060" Dia x 5.500" L (26.92mm x 139.70mm)
Requires Holder
600 VAC
300 VDC
LPS-RK-600SP
FUSE CRTRDGE 600A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
600A
Cartridge
Cylindrical, Blade Terminal (Bolt)
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
2.880" Dia x 13.380" L (73.15mm x 339.85mm)
Bolt Mount
600 VAC
300 VDC
LPS-RK-125SP
FUSE CRTRDGE 125A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
125A
Cartridge
Cylindrical, Blade Terminal (Bolt)
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
1.610" Dia x 9.630" L (40.89mm x 244.60mm)
Bolt Mount
600 VAC
300 VDC
LPS-RK-150SP
FUSE CRTRDGE 150A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
150A
Cartridge
Cylindrical, Blade Terminal (Bolt)
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
1.610" Dia x 9.630" L (40.89mm x 244.60mm)
Bolt Mount
600 VAC
300 VDC
LPS-RK-200SP
FUSE CRTRDGE 200A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
200A
Cartridge
Cylindrical, Blade Terminal (Bolt)
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
1.610" Dia x 9.630" L (40.89mm x 244.60mm)
Bolt Mount
600 VAC
300 VDC
LPS-RK-20SP
FUSE CARTRIDGE 20A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
20A
Cartridge
Cartridge, Non-Standard
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
0.810" Dia x 5.000" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
LPS-RK-30SP
FUSE CARTRIDGE 30A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
30A
Cartridge
Cartridge, Non-Standard
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
0.810" Dia x 5.000" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
300 VDC
LPS-RK-400SP
FUSE CRTRDGE 400A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
400A
Cartridge
Cylindrical, Blade Terminal (Bolt)
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
2.360" Dia x 11.630" L (59.94mm x 295.40mm)
Bolt Mount
600 VAC
300 VDC
LPS-RK-300SP
FUSE CRTRDGE 300A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
300A
Cartridge
Cylindrical, Blade Terminal (Bolt)
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
2.360" Dia x 11.630" L (59.94mm x 295.40mm)
Bolt Mount
600 VAC
300 VDC
LPS-RK-100SP
FUSE CRTRDGE 100A 600VAC/300VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
CE, CSA, UL
Slow Blow
100A
Cartridge
Cylindrical, Blade Terminal (Bolt)
Low-Peak™ LPS
Motor Protection, Transformer Protection
RK1
300kA AC, 100kA DC
1.110" Dia x 7.880" L (28.19mm x 200.15mm)
Bolt Mount
600 VAC
300 VDC

Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.