ECSR Series, Electrical, Specialty Fuses

Results:
62
Manufacturer
Series
Current Rating (Amps)
Size / Dimension
Package / Case
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Voltage Rating - DC
Voltage Rating - AC
Class
Features
Results remaining62
Applied Filters:
ECSR
Select
ImageProduct DetailPriceAvailabilityECAD ModelVoltage Rating - DCFeaturesOperating TemperatureApproval AgencyCurrent Rating (Amps)Response TimeFuse TypePackage / CaseBreaking Capacity @ Rated VoltageSeriesApplicationsClassSize / DimensionMounting TypeVoltage Rating - AC
ECSR1.25
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
1.25A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR2.25
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
2.25A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR350
FUSE CRTRDGE 350A 600VAC CYLINDR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
350A
Slow Blow
Cartridge
Cylindrical, Blade Terminals
200kA
ECSR
Electrical, Industrial
RK5
2.340" Dia x 11.630" L (59.44mm x 295.40mm)
Requires Holder
600 VAC
ECSR400
FUSE CRTRDGE 400A 600VAC CYLINDR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
400A
Slow Blow
Cartridge
Cylindrical, Blade Terminals
200kA
ECSR
Electrical, Industrial
RK5
2.340" Dia x 11.630" L (59.44mm x 295.40mm)
Requires Holder
600 VAC
ECSR35
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
35A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
1.060" Dia x 5.50" L (26.92mm x 139.70mm)
Requires Holder
600 VAC
ECSR40
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
40A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
1.060" Dia x 5.50" L (26.92mm x 139.70mm)
Requires Holder
600 VAC
ECSR45
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
45A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
1.060" Dia x 5.50" L (26.92mm x 139.70mm)
Requires Holder
600 VAC
ECSR50
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
50A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
1.060" Dia x 5.50" L (26.92mm x 139.70mm)
Requires Holder
600 VAC
ECSR60
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
60A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
1.060" Dia x 5.50" L (26.92mm x 139.70mm)
Requires Holder
600 VAC
ECSR2.8
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
2.8A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR.3
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
300mA
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR500
FUSE CRTRDGE 500A 600VAC CYLINDR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
500A
Slow Blow
Cartridge
Cylindrical, Blade Terminals
200kA
ECSR
Electrical, Industrial
RK5
2.880" Dia x 13.380" L (73.15mm x 339.85mm)
Requires Holder
600 VAC
ECSR.15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
150mA
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR.1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
100mA
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR.25
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
250mA
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR.4
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
400mA
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR30
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
30A
Slow Blow
Cartridge
Cartridge, Non-Standard
200kA
ECSR
Electrical, Industrial
RK5
0.810" Dia x 5.00" L (20.57mm x 127.00mm)
Requires Holder
600 VAC
ECSR110
FUSE CRTRDGE 110A 600VAC CYLINDR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
110A
Slow Blow
Cartridge
Cylindrical, Blade Terminals
200kA
ECSR
Electrical, Industrial
RK5
1.610" Dia x 9.630" L (40.89mm x 244.60mm)
Requires Holder
600 VAC
ECSR125
FUSE CRTRDGE 125A 600VAC CYLINDR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
125A
Slow Blow
Cartridge
Cylindrical, Blade Terminals
200kA
ECSR
Electrical, Industrial
RK5
1.610" Dia x 9.630" L (40.89mm x 244.60mm)
Requires Holder
600 VAC
ECSR175
FUSE CRTRDGE 175A 600VAC CYLINDR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
CE, CSA, UL
175A
Slow Blow
Cartridge
Cylindrical, Blade Terminals
200kA
ECSR
Electrical, Industrial
RK5
1.610" Dia x 9.630" L (40.89mm x 244.60mm)
Requires Holder
600 VAC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.