BHCL Series, Electrical, Specialty Fuses

Results:
69
Manufacturer
Series
Current Rating (Amps)
Size / Dimension
Breaking Capacity @ Rated Voltage
Mounting Type
Package / Case
Features
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Voltage Rating - DC
Voltage Rating - AC
Class
Results remaining69
Applied Filters:
BHCL
Select
ImageProduct DetailPriceAvailabilityECAD ModelVoltage Rating - DCFeaturesOperating TemperatureApproval AgencyResponse TimeClassCurrent Rating (Amps)Fuse TypePackage / CaseSeriesApplicationsBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeVoltage Rating - AC
15CLE-300E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
300A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 23.900" L (76.20mm x 607.06mm)
Requires Holder
15.5 kVAC
15CLE-10E-D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
10A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 23.900" L (76.20mm x 607.06mm)
Requires Holder
15.5 kVAC
15BHLE-250E
FUSE CARTRDGE 250A 15.5KVAC BOLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Indicating
-
UL
-
-
250A
Cartridge
Cylindrical, Blade Terminal (Bolt)
BHCL
Transformer Protection
63kA
-
Bolt Mount
15.5 kVAC
15BHCL-300E
FUSE CARTRDGE 300A 15.5KVAC BOLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
300A
Cartridge
Cylindrical, Blade Terminal (Bolt)
BHCL
Transformer Protection
50kA
-
Bolt Mount
15.5 kVAC
15BHCL-400E
FUSE CARTRDGE 400A 15.5KVAC BOLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
400A
Cartridge
Cylindrical, Blade Terminal (Bolt)
BHCL
Transformer Protection
50kA
-
Bolt Mount
15.5 kVAC
15HLE-150E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
150A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
-
Requires Holder
15.5 kVAC
15HLE-175E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
175A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
-
Requires Holder
15.5 kVAC
15HLE-200E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
200A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
-
Requires Holder
15.5 kVAC
15HCL-10E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
10A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-15E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
15A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-25E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
25A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-20E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
20A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-40E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
40A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-50E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
50A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-65E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
65A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-30E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
30A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15BHLE-25E
FUSE CARTRIDGE 25A 15.5KVAC BOLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Indicating
-
UL
-
-
25A
Cartridge
Cylindrical, Blade Terminal (Bolt)
BHCL
Transformer Protection
63kA
3.000" Dia x 22.200" L (76.20mm x 563.88mm)
Bolt Mount
15.5 kVAC
15BHLE-125E
FUSE CARTRDGE 125A 15.5KVAC BOLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Indicating
-
UL
-
-
125A
Cartridge
Cylindrical, Blade Terminal (Bolt)
BHCL
Transformer Protection
63kA
3.000" Dia x 22.200" L (76.20mm x 563.88mm)
Bolt Mount
15.5 kVAC
15HCL-100E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
100A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC
15HCL-80E
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
UL
-
-
80A
Cartridge
Cartridge, Non-Standard
BHCL
Transformer Protection
63kA
3.000" Dia x 22.800" L (76.20mm x 579.12mm)
Requires Holder
15.5 kVAC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.