308 Series, Electrical, Specialty Fuses

Results:
7
Manufacturer
Series
Current Rating (Amps)
Operating Temperature
Applications
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Features
Class
Results remaining7
Applied Filters:
308
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeOperating TemperatureFeaturesClassResponse TimePackage / CaseBreaking Capacity @ Rated VoltageSeriesFuse TypeCurrent Rating (Amps)ApplicationsApproval AgencySize / DimensionVoltage Rating - ACVoltage Rating - DC
0308.375UR
FUSE BRD MNT 375MA 24VAC/30VDC
1+
$7.2000
5+
$6.8000
10+
$6.4000
Quantity
392 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-40°C ~ 70°C
Intrinsically Safe
-
Slow Blow
2-SMD, J-Lead
50A
308
Board Mount
375mA
Hazardous Locations
cURus, Ex, IEC, IECEx
0.213" L x 0.150" W x 0.144" H (5.40mm x 3.80mm x 3.65mm)
24 VAC
30 VDC
0308.500UR
FUSE BRD MNT 500MA 24VAC/30VDC
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-40°C ~ 70°C
Intrinsically Safe
-
Slow Blow
2-SMD, J-Lead
50A
308
Board Mount
500mA
Hazardous Locations
cURus, Ex, IEC, IECEx
0.213" L x 0.150" W x 0.144" H (5.40mm x 3.80mm x 3.65mm)
24 VAC
30 VDC
030801.5UR
FUSE BRD MNT 1.5A 24VAC/30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-40°C ~ 70°C
Intrinsically Safe
-
Slow Blow
2-SMD, J-Lead
50A
308
Board Mount
1.5A
Hazardous Locations
cURus, Ex, IEC, IECEx
0.213" L x 0.150" W x 0.144" H (5.40mm x 3.80mm x 3.65mm)
24 VAC
30 VDC
0308.250UR
FUSE BRD MNT 250MA 24VAC/30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-40°C ~ 70°C
Intrinsically Safe
-
Slow Blow
2-SMD, J-Lead
50A
308
Board Mount
250mA
Hazardous Locations
cURus, Ex, IEC, IECEx
0.213" L x 0.150" W x 0.144" H (5.40mm x 3.80mm x 3.65mm)
24 VAC
30 VDC
03081.25UR
FUSE BRD MNT 1.25A 24VAC/30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-40°C ~ 70°C
Intrinsically Safe
-
Slow Blow
2-SMD, J-Lead
50A
308
Board Mount
1.25A
Hazardous Locations
cURus, Ex, IEC, IECEx
0.213" L x 0.150" W x 0.144" H (5.40mm x 3.80mm x 3.65mm)
24 VAC
30 VDC
0308001.UR
FUSE BRD MNT 1A 24VAC/30VDC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-40°C ~ 70°C
Intrinsically Safe
-
Slow Blow
2-SMD, J-Lead
50A
308
Board Mount
1A
Hazardous Locations
cURus, Ex, IEC, IECEx
0.213" L x 0.150" W x 0.144" H (5.40mm x 3.80mm x 3.65mm)
24 VAC
30 VDC
0308.750UR
FUSE BRD MNT 750MA 24VAC/30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-40°C ~ 70°C
Intrinsically Safe
-
Slow Blow
2-SMD, J-Lead
50A
308
Board Mount
750mA
Hazardous Locations
cURus, Ex, IEC, IECEx
0.213" L x 0.150" W x 0.144" H (5.40mm x 3.80mm x 3.65mm)
24 VAC
30 VDC

About  Electrical, Specialty Fuses

Circuit protection, specifically specialty fuses in the electrical domain, refers to a range of products designed to safeguard electrical circuits from over-current faults. These specialty fuses are distinct from standard fuses and serve as primary circuit protection devices. They are engineered to respond to excessive current flow by triggering the destruction of a conductive element within the device, effectively interrupting the circuit and preventing damage to connected components. One key characteristic of specialty fuses is their classification under the UL248 standard as non-supplementary, emphasizing their primary role in safeguarding main circuits. Additionally, certain specialty fuses are certified for use in hazardous or explosive environments, meeting stringent safety requirements to mitigate ignition or explosion risks. These fuses exhibit form factors that differentiate them from those commonly used for supplementary equipment protection, such as fuses with indication functions or fusible cable links. Furthermore, specialized versions cater to specific applications, including the protection of telecommunications circuits or multimeters. The proper selection and utilization of these circuit protection accessories are crucial in ensuring the safety and reliability of electrical systems. Adherence to relevant safety standards and guidelines is essential for the correct installation and maintenance of these devices, which play a critical role in preventing over-current faults and supporting the secure operation of diverse applications.