637 Series, D-Sub Connector Assemblies

Results:
840
Manufacturer
Series
Number of Positions
Flange Feature
Shell Size, Connector Layout
Number of Rows
Contact Finish Thickness
Shell Material, Finish
Termination
Mounting Type
Features
Primary Material
Ingress Protection
Current Rating (Amps)
Contact Finish
Contact Type
Material Flammability Rating
Backset Spacing
Connector Style
Connector Type
Results remaining840
Applied Filters:
637
Select
ImageProduct DetailPriceAvailabilityECAD ModelIngress ProtectionNumber of RowsMounting TypeContact FinishContact Finish ThicknessMaterial Flammability RatingCurrent Rating (Amps)TerminationConnector TypeNumber of PositionsPrimary MaterialSeriesConnector StyleShell Size, Connector LayoutContact TypeFlange FeatureShell Material, FinishBackset SpacingFeatures
637-078-632-069
CONN D-SUB HD PLUG 78P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
4
Free Hanging (In-Line)
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
78
-
637
D-Sub, High Density
5 (DD, D) High Density
Signal
Board Side (4-40)
Steel, Nickel Plated
-
Grounding Indents, Shielded
637-026-232-261
CONN D-SUB HD PLUG 26P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
Flash
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
26
-
637
D-Sub, High Density
2 (DA, A) High Density
Signal
Housing/Shell (Unthreaded)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-044-330-268
CONN D-SUB HD PLUG 44P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
15.0µin (0.38µm)
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Mating Side (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-015-330-242
CONN D-SUB HD PLUG 15P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
15.0µin (0.38µm)
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
15
-
637
D-Sub, High Density
1 (DE, E) High Density
Signal
Housing/Shell (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-044-630-246
CONN D-SUB HD PLUG 44P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Housing/Shell (4-40)
Steel, Tin Plated
-
Board Lock, Grounding Indents, Shielded
637-044-632-243
CONN D-SUB HD PLUG 44P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Mating Side, Female Screwlock (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-044-632-063
CONN D-SUB HD PLUG 44P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Mating Side, Female Screwlock (4-40)
Steel, Nickel Plated
-
Grounding Indents, Shielded
637-044-630-066
CONN D-SUB HD PLUG 44P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Housing/Shell (4-40)
Steel, Nickel Plated
-
Board Lock, Grounding Indents, Shielded
637-044-630-247
CONN D-SUB HD PLUG 44P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Mating Side (4-40)
Steel, Tin Plated
-
Board Lock, Grounding Indents, Shielded
637-026-230-061
CONN D-SUB HD PLUG 26P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
Flash
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
26
-
637
D-Sub, High Density
2 (DA, A) High Density
Signal
Housing/Shell (Unthreaded)
Steel, Nickel Plated
-
Grounding Indents, Shielded
637-062-330-248
CONN D-SUB HD PLUG 62P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
15.0µin (0.38µm)
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
62
-
637
D-Sub, High Density
4 (DC, C) High Density
Signal
Mating Side (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-062-230-247
CONN D-SUB HD PLUG 62P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
Flash
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
62
-
637
D-Sub, High Density
4 (DC, C) High Density
Signal
Mating Side (4-40)
Steel, Tin Plated
-
Board Lock, Grounding Indents, Shielded
637-062-232-263
CONN D-SUB HD PLUG 62P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
Flash
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
62
-
637
D-Sub, High Density
4 (DC, C) High Density
Signal
Mating Side, Female Screwlock (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-062-632-061
CONN D-SUB HD PLUG 62P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
62
-
637
D-Sub, High Density
4 (DC, C) High Density
Signal
Housing/Shell (Unthreaded)
Steel, Nickel Plated
-
Grounding Indents, Shielded
637-062-632-046
637 SERIES VERTICAL D-SUB PLUG C
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
30.0µin (0.76µm)
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
62
-
637
D-Sub, High Density
4 (DC, C) High Density
Signal
Housing/Shell (4-40)
Steel, Nickel Plated
-
Board Lock, Grounding Indents, Shielded
637-078-232-268
CONN D-SUB HD PLUG 78P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
4
Free Hanging (In-Line)
Gold
Flash
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
78
-
637
D-Sub, High Density
5 (DD, D) High Density
Signal
Mating Side (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-044-230-266
CONN D-SUB HD PLUG 44P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
Flash
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Housing/Shell (4-40)
Steel, Tin Plated
-
Board Lock, Grounding Indents, Shielded
637-044-232-263
CONN D-SUB HD PLUG 44P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
Flash
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
44
-
637
D-Sub, High Density
3 (DB, B) High Density
Signal
Mating Side, Female Screwlock (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-062-230-249
CONN D-SUB HD PLUG 62P PNL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Panel Mount, Through Hole
Gold
Flash
UL94 V-0
3A per Contact
Solder
Plug, Male Pins
62
-
637
D-Sub, High Density
4 (DC, C) High Density
Signal
Board Side (4-40)
Steel, Tin Plated
-
Grounding Indents, Shielded
637-026-332-247
CONN D-SUB HD PLUG 26P SLDR CUP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
3
Free Hanging (In-Line)
Gold
15.0µin (0.38µm)
UL94 V-0
3A per Contact
Solder Cup
Plug, Male Pins
26
-
637
D-Sub, High Density
2 (DA, A) High Density
Signal
Mating Side (4-40)
Steel, Tin Plated
-
Board Lock, Grounding Indents, Shielded

About  D-Sub Connector Assemblies

The products within this family are specifically developed to cater to standard D-style and related connectors, offering a range of ancillary functions that enhance their overall performance and usability. One significant function provided by these products is the sealing of a connector assembly. They ensure a secure and reliable seal between the connector and its mating counterpart, protecting against environmental factors such as moisture, dust, and debris. This sealing feature helps maintain the integrity of the connection and prolongs the lifespan of the connectors. Mechanical fixation is another essential purpose served by these products. They offer mechanisms to firmly attach the connectors, preventing accidental disconnection or movement. This ensures a stable and reliable connection, minimizing the risk of signal loss or interruption. To avoid improper connections, these products also provide keying options for the connectors. Keying features allow for the proper alignment and mating of connectors, discouraging connections with incompatible counterparts. This keying functionality enhances system reliability and prevents potential damage or malfunction due to incorrect connections. Cable strain relief is yet another crucial function offered by these products. They are designed to alleviate stress on the cables connected to the assembly, reducing the risk of cable damage or breakage. This strain relief capability ensures the longevity and durability of the cable assembly, particularly in applications where the cables may be subject to frequent movement or bending. Furthermore, these products may facilitate system diagnostics by incorporating additional features. For example, they may include indicators or labeling options to aid in the identification and troubleshooting of specific connectors or connections within a system. This diagnostic functionality streamlines maintenance and minimizes downtime. In summary, the products within this family are specifically designed for use with standard D-style and related connectors, offering a range of ancillary functions. These functions include sealing of connector assemblies, mechanical fixation, avoidance of improper connections, cable strain relief, facilitating system diagnostics, and more. By incorporating these products, users can enhance the performance, reliability, and longevity of their connector assemblies.