AT Series, Current Sensors

Results:
20
Manufacturer
Series
Current - Sensing
Voltage - Supply
Output
Polarization
Operating Temperature
Response Time
Current - Supply (Max)
Accuracy
Linearity
Frequency
For Measuring
Grade
Mounting Type
Supplier Device Package
Sensitivity
Qualification
Package / Case
Number of Channels
Sensor Type
Results remaining20
Applied Filters:
AT
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypePackage / CaseSupplier Device PackageOperating TemperatureSensitivityLinearityVoltage - SupplyResponse TimeCurrent - Supply (Max)SeriesNumber of ChannelsGradeAccuracyFor MeasuringSensor TypeCurrent - SensingOutputFrequencyPolarizationQualification
AT 150 B10
SENSOR CURRENT XFMR 150A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
150A
Ratiometric, 0 V ~ 10 V
50/60Hz
Bidirectional
-
AT 50 B5
SENSOR CURRENT XFMR 50A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
50A
Ratiometric, 0 V ~ 5 V
50/60Hz
Bidirectional
-
AT 100 B5
SENSOR CURRENT XFMR 100A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
100A
Ratiometric, 0 V ~ 5 V
50/60Hz
Bidirectional
-
AT 100 B420L
SENSOR CURRENT XFMR 100A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
20V ~ 30V
100ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
100A
Ratiometric, 4mA ~ 20mA
50/60Hz
Bidirectional
-
AT 20 B10
SENSOR CURRENT XFMR 20A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
20A
Ratiometric, 0 V ~ 10 V
50/60Hz
Bidirectional
-
AT 50 B10
SENSOR CURRENT XFMR 50A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
50A
Ratiometric, 0 V ~ 10 V
50/60Hz
Bidirectional
-
AT 5 B5
SENSOR CURRENT XFMR 5A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
5A
Ratiometric, 0 V ~ 5 V
50/60Hz
Bidirectional
-
AT 50 B420L
SENSOR CURRENT XFMR 50A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
20V ~ 30V
100ms
30mA
AT
1
-
±1.5%
AC
Transformer w/Conditioning
50A
Ratiometric, 4mA ~ 20mA
50/60Hz
Bidirectional
-
AT 150 B420L
SENSOR CURRENT XFMR 150A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
20V ~ 30V
100ms
30mA
AT
1
-
±1.5%
AC
Transformer w/Conditioning
150A
Ratiometric, 4mA ~ 20mA
50/60Hz
Bidirectional
-
AT 5 B10
SENSOR CURRENT XFMR 5A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
5A
Ratiometric, 0 V ~ 10 V
50/60Hz
Bidirectional
-
AT 5 B420L
SENSOR CURRENT XFMR 5A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
20V ~ 30V
100ms
30mA
AT
1
-
±1.5%
AC
Transformer w/Conditioning
5A
Ratiometric, 4mA ~ 20mA
50/60Hz
Bidirectional
-
AT 100 B10
SENSOR CURRENT XFMR 100A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
100A
Ratiometric, 0 V ~ 10 V
50/60Hz
Bidirectional
-
AT 20 B5
SENSOR CURRENT XFMR 20A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
20A
Ratiometric, 0 V ~ 5 V
50/60Hz
Bidirectional
-
AT 150 B5
SENSOR CURRENT XFMR 150A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
Self Powered
300ms
-
AT
1
-
±1.5%
AC
Transformer w/Conditioning
150A
Ratiometric, 0 V ~ 5 V
50/60Hz
Bidirectional
-
AT 20 B420L
SENSOR CURRENT XFMR 20A AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 60°C
-
±0.5%
20V ~ 30V
100ms
30mA
AT
1
-
±1.5%
AC
Transformer w/Conditioning
20A
Ratiometric, 4mA ~ 20mA
50/60Hz
Bidirectional
-
AT1-420-24L-FT
AC TRANSDUCER 50 A, 4-20 MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 50°C
-
-
5V ~ 40V
300ms
-
AT
1
-
±1%
AC
Transformer w/Conditioning
10A, 20A, 50A (Selectable)
Ratiometric, 4mA ~ 20mA
20Hz ~ 100Hz
Unidirectional
-
AT2-420-24L-FT
AC TRANSDUCER 200 A, 4-20 MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 50°C
-
-
5V ~ 40V
300ms
-
AT
1
-
±1%
AC
Transformer w/Conditioning
100A, 150A, 200A (Selectable)
Ratiometric, 4mA ~ 20mA
20Hz ~ 100Hz
Unidirectional
-
AT0-420-24L-FT
AC TRANSDUCER 5 A, 4-20 MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 50°C
-
-
5V ~ 40V
300ms
-
AT
1
-
±1%
AC
Transformer w/Conditioning
2A, 5A (Selectable)
Ratiometric, 4mA ~ 20mA
20Hz ~ 100Hz
Unidirectional
-
AT1-420-24L-SP
AC TRANSDUCER 50 A, 4-20 MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 50°C
-
-
5V ~ 40V
300ms
-
AT
1
-
±1%
AC
Transformer w/Conditioning
10A, 20A, 50A (Selectable)
Ratiometric, 4mA ~ 20mA
20Hz ~ 100Hz
Unidirectional
-
AT2-420-24L-SP
AC TRANSDUCER 200 A, 4-20 MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Module
-
-20°C ~ 50°C
-
-
5V ~ 40V
300ms
-
AT
1
-
±1%
AC
Transformer w/Conditioning
100A, 150A, 200A (Selectable)
Ratiometric, 4mA ~ 20mA
20Hz ~ 100Hz
Unidirectional
-

About  Current Sensors

Current sensors are meticulously engineered to identify and react to variations in the electrical current within a wire or circuit. These sensors come in various types, including current switch, flux gate, hall effect, current indicator, current sensor, magnetic modulator, magnetoresistive, and transformer with conditioning. They cover a wide range of current sensing capabilities, spanning from programmable sensors capable of measuring currents as low as 5mA to robust models designed for measuring currents as high as 2500A, whether it be AC or DC current. The diverse range of current sensors enables their application across numerous sectors, such as power systems, industrial equipment, renewable energy installations, and automotive systems. These sensors play a pivotal role in monitoring and controlling electrical currents, ensuring safety, efficiency, and optimal performance within various electrical and electronic systems.