Automation Components, Inc. (ACI) specializes in the design, production, and supply of cutting-edge building automation sensors tailored for the heating, ventilation, and air conditioning (HVAC) sector. Since its inception in 1991, ACI has evolved from a modest enterprise into a prominent player renowned for its superior automation sensor solutions. We take pride in our industry recognition and the positive contributions we have made to our community. ACI's diverse range of products encompasses temperature sensors, relative humidity sensors, current sensors, pressure sensors, gas sensors, and wireless sensors.

Current Sense Transformers

Results:
78
Series
Height - Seated (Max)
Size / Dimension
Current Rating (Amps)
Type
Frequency Range
Mounting Type
Inductance
Turns Ratio - Primary
Current Ratio
Termination Style
Ratings
DC Resistance (DCR)
ET (Volt-Time)
Results remaining78
Applied Filters:
Automation Components, Inc.
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesMounting TypeCurrent Rating (Amps)Termination StyleRatingsDC Resistance (DCR)ET (Volt-Time)Frequency RangeTypeCurrent RatioHeight - Seated (Max)InductanceTurns Ratio - PrimarySize / Dimension
LE11300
CURR SENSE XFMR CHAS MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
Wire Leads
-
-
-
50Hz ~ 60Hz
Invasive
-
2.880" (73.15mm)
-
Secondary:-
2.730" L x 2.190" W (69.34mm x 55.63mm)
RCT24-2500
CURR XFMR ROGOWSKI COIL IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
-
Wire Leads
-
-
-
20Hz ~ 5kHz
Non-Invasive (Split Core)
-
0.610" (15.50mm)
-
Secondary:Rogowski Coil
-
RCT24-5000
CURR XFMR ROGOWSKI COIL IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
-
Wire Leads
-
-
-
20Hz ~ 5kHz
Non-Invasive (Split Core)
-
0.610" (15.50mm)
-
Secondary:Rogowski Coil
-
LE170
CURR SENSE XFMR CHAS MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
Wire Leads
-
-
-
50Hz ~ 60Hz
Invasive
-
3.060" (77.72mm)
-
Secondary:-
4.250" L x 2.520" W (107.95mm x 64.00mm)
RCT16-2500
CURR XFMR ROGOWSKI COIL IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
-
Wire Leads
-
-
-
20Hz ~ 5kHz
Non-Invasive (Split Core)
-
0.610" (15.50mm)
-
Secondary:Rogowski Coil
-
ACUCT-200R-400:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
400 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
1.260" (32.00mm)
-
Secondary:-
4.370" L x 4.370" W (111.00mm x 111.00mm)
ACUCT-200R-800:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
800 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
1.260" (32.00mm)
-
Secondary:-
4.370" L x 4.370" W (111.00mm x 111.00mm)
ACUCT-200-800:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
800 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
5.020" (127.50mm)
-
Secondary:-
5.000" L x 1.181" W (127.00mm x 30.00mm)
ACUCT-H100-200:333-10M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
200 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
2.780" (70.60mm)
-
Secondary:-
1.732" L x 1.535" W (44.00mm x 39.00mm)
LE117
CURR SENSE XFMR CHAS MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
Wire Leads
-
-
-
50Hz ~ 60Hz
Invasive
-
2.900" (73.66mm)
-
Secondary:-
2.820" L x 2.190" W (71.63mm x 55.63mm)
ACUCT-H040-60:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
60 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
1.654" (42.00mm)
-
Secondary:-
1.024" L x 0.945" W (26.00mm x 24.00mm)
ACUCT-H100-100:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
100 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
2.780" (70.60mm)
-
Secondary:-
1.732" L x 1.535" W (44.00mm x 39.00mm)
ACUCT-H100-200:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
200 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
2.780" (70.60mm)
-
Secondary:-
1.732" L x 1.535" W (44.00mm x 39.00mm)
ACUCT-075-100:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
100 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
2.126" (54.00mm)
-
Secondary:-
2.008" L x 0.630" W (51.00mm x 16.00mm)
ACUCT-075-50:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
50 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
2.126" (54.00mm)
-
Secondary:-
2.008" L x 0.630" W (51.00mm x 16.00mm)
ACUCT-S77-200:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
200 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Solid Core)
-
1.142" (29.00mm)
-
Secondary:-
2.008" L x 1.890" W (51.00mm x 48.00mm)
ACUCT-S77-100:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
100 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Solid Core)
-
1.142" (29.00mm)
-
Secondary:-
2.008" L x 1.890" W (51.00mm x 48.00mm)
ACUCT-H040-20:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
20 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
1.654" (42.00mm)
-
Secondary:-
1.024" L x 0.945" W (26.00mm x 24.00mm)
ACUCT-H040-50:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
50 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
1.654" (42.00mm)
-
ACUCT-H040-40:333
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
40 A
Wire Leads
-
-
-
50Hz ~ 60Hz
Non-Invasive (Split Core)
-
1.654" (42.00mm)
-
Secondary:-
1.024" L x 0.945" W (26.00mm x 24.00mm)

About  Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.