TCS Series, Current Sense Transformers

Results:
8
Manufacturer
Series
DC Resistance (DCR)
Inductance
Turns Ratio - Primary
Current Rating (Amps)
Turns Ratio - Primary:Secondary
Frequency Range
Current Ratio
Termination Style
Height - Seated (Max)
Mounting Type
Size / Dimension
Ratings
Type
ET (Volt-Time)
Results remaining8
Applied Filters:
TCS
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeCurrent Rating (Amps)InductanceTermination StyleSeriesRatingsET (Volt-Time)Height - Seated (Max)Frequency RangeTypeCurrent RatioDC Resistance (DCR)Size / DimensionTurns Ratio - Primary
TCS-02
CURR SENSE XFMR 1:30 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
180 µH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 870mOhm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
Secondary:1:30
TCS-04
CURR SENSE XFMR 1:50 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
500 µH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 1.5Ohm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
TCS-07
CURR SENSE XFMR 1:100 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2 mH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 5.9Ohm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
Secondary:1:100
TCS-03
CURR SENSE XFMR 1:40 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
320 µH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 1.14Ohm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
Secondary:1:40
TCS-06
CURR SENSE XFMR 1:70 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
980 µH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 4.75Ohm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
TCS-01
CURR SENSE XFMR 1:20 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
80 µH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 550mOhm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
Secondary:1:20
TCS-05
CURR SENSE XFMR 1:60 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
720 µH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 1.75Ohm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
Secondary:1:60
TCS-08
CURR SENSE XFMR 1:125 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
3 mH
Gull Wing
TCS
-
-
0.205" (5.20mm)
250kHz Min
Invasive
-
6mOhm Primary, 7.7Ohm Secondary
0.276" L x 0.331" W (7.00mm x 8.40mm)
Secondary:1:125

About  Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.