PA1005.XXXNL Series, Current Sense Transformers

Results:
7
Manufacturer
Series
DC Resistance (DCR)
Inductance
Turns Ratio - Primary
Frequency Range
Size / Dimension
Current Ratio
Termination Style
Height - Seated (Max)
Current Rating (Amps)
Mounting Type
Ratings
Type
ET (Volt-Time)
Results remaining7
Applied Filters:
PA1005.XXXNL
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeInductanceHeight - Seated (Max)Termination StyleRatingsCurrent Rating (Amps)ET (Volt-Time)SeriesFrequency RangeTypeCurrent RatioDC Resistance (DCR)Size / DimensionTurns Ratio - Primary
PA1005.100NLT
CURR SENSE XFMR 1:100 20A SMD
1+
$0.9127
5+
$0.8620
10+
$0.8113
Quantity
3,735 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
2 mH
0.217" (5.50mm)
Gull Wing
-
20 A
-
PA1005.XXXNL
50kHz ~ 1MHz
Invasive
-
0.75mOhm Primary, 5.5Ohm Secondary
0.284" L x 0.330" W (7.21mm x 8.38mm)
Secondary:1:100
PA1005.050NLT
CURR SENSE XFMR 1:50 20A SMD
1+
$5.0704
5+
$4.7887
10+
$4.5070
Quantity
70 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
500 µH
0.217" (5.50mm)
Gull Wing
-
20 A
-
PA1005.XXXNL
50kHz ~ 1MHz
Invasive
-
0.75mOhm Primary, 1.5Ohm Secondary
0.284" L x 0.330" W (7.21mm x 8.38mm)
Secondary:1:50
PA1005.040NL
XFMR CURRENT SENSE 1:40 NPB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
320 µH
0.217" (5.50mm)
Gull Wing
-
20 A
-
PA1005.XXXNL
20kHz ~ 1MHz
Invasive
-
0.75mOhm Primary, 1.14Ohm Secondary Max
-
Secondary:1:40
PA1005.070NLT
CURR SENSE XFMR 1:70 20A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
980 µH
0.217" (5.50mm)
Gull Wing
-
20 A
-
PA1005.XXXNL
50kHz ~ 1MHz
Invasive
-
0.75mOhm Primary, 4.75Ohm Secondary
0.284" L x 0.330" W (7.21mm x 8.38mm)
Secondary:1:70
PA1005.020NL
XFMR CURRENT SENSE 1:20 NPB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
80 µH
0.217" (5.50mm)
Gull Wing
-
20 A
-
PA1005.XXXNL
20kHz ~ 1MHz
Invasive
-
0.75mOhm Primary, 550mOhm Secondary Max
-
Secondary:1:20
PA1005.060NL
XFMR CURRENT SENSE 1:60 NPB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
720 µH
0.217" (5.50mm)
Gull Wing
-
20 A
-
PA1005.XXXNL
20kHz ~ 1MHz
Invasive
-
0.75mOhm Primary, 2.5Ohm Secondary Max
-
Secondary:1:60
PA1005.030NL
XFMR CURRENT SENSE 1:30 NPB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
180 µH
0.217" (5.50mm)
Gull Wing
-
20 A
-
PA1005.XXXNL
20kHz ~ 1MHz
Invasive
-
0.75mOhm Primary, 870mOhm Secondary Max
-
Secondary:1:30

About  Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.