CR2DA Series, Current Sense Transformers

Results:
4
Manufacturer
Series
Current Ratio
Current Rating (Amps)
Frequency Range
Termination Style
Height - Seated (Max)
Mounting Type
Size / Dimension
DC Resistance (DCR)
Ratings
Inductance
Type
Turns Ratio - Primary
ET (Volt-Time)
Results remaining4
Applied Filters:
CR2DA
Select
ImageProduct DetailPriceAvailabilityECAD ModelTermination StyleMounting TypeRatingsDC Resistance (DCR)Current Rating (Amps)ET (Volt-Time)SeriesFrequency RangeTypeCurrent RatioSize / DimensionHeight - Seated (Max)InductanceTurns Ratio - Primary
CR2DARL-101
CURR SENSE XFMR 100A IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
-
-
100 A
-
CR2DA
50Hz ~ 400Hz
Non-Invasive (Solid Core)
100:5
2.468" Dia (62.70mm)
1.752" (44.50mm)
-
Secondary:-
CR2DARL-301
CURR SENSE XFMR 300A IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
-
-
300 A
-
CR2DA
50Hz ~ 400Hz
Non-Invasive (Solid Core)
300:5
2.468" Dia (62.70mm)
1.752" (44.50mm)
-
Secondary:-
CR2DARL-500
CURR SENSE XFMR 50A IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
-
-
50 A
-
CR2DA
50Hz ~ 400Hz
Non-Invasive (Solid Core)
50:5
2.468" Dia (62.70mm)
1.752" (44.50mm)
-
Secondary:-
CR2DARL-151
CURR SENSE XFMR 150A IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Free Hanging (In-Line)
-
-
150 A
-
CR2DA
50Hz ~ 400Hz
Non-Invasive (Solid Core)
150:5
2.468" Dia (62.70mm)
1.752" (44.50mm)
-
Secondary:-

About  Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.