AS Series, Current Sense Transformers

Results:
43
Manufacturer
Series
DC Resistance (DCR)
Turns Ratio - Primary
Height - Seated (Max)
Size / Dimension
ET (Volt-Time)
Inductance
Current Rating (Amps)
Frequency Range
Termination Style
Mounting Type
Type
Current Ratio
Ratings
Results remaining43
Applied Filters:
AS
Select
ImageProduct DetailPriceAvailabilityECAD ModelCurrent Rating (Amps)Mounting TypeTermination StyleRatingsSeriesFrequency RangeTypeInductanceET (Volt-Time)Current RatioDC Resistance (DCR)Size / DimensionHeight - Seated (Max)
AS-115
CURR SENSE XFMR 1:750CT 30A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
PC Pin
-
AS
20kHz ~ 200kHz
Non-Invasive (Solid Core)
1.68 mH
3750VµS
-
21.5Ohm Max
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-100
CURR SENSE XFMR 1:50 T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
PC Pin
-
AS
20kHz ~ 200kHz
Non-Invasive (Solid Core)
6 mH
175VµS
-
600mOhm Max
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-101
CURR SENSE XFMR 1:100 15A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
15 A
Through Hole
PC Pin
-
AS
20kHz ~ 200kHz
Non-Invasive (Solid Core)
25 mH
350VµS
-
1.1Ohm Secondary
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-104
CURR SENSE XFMR 1:500 15A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
15 A
Through Hole
PC Pin
-
AS
20kHz ~ 200kHz
Non-Invasive (Solid Core)
700 mH
1500VµS
-
25Ohm Secondary
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-102
XFRMR CURR 15A 1:200 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-110
XFRMR CURR 15A 1:50CT VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-104
XFRMR CURR 15A 1:500 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-102
CURR SENSE XFMR 1:200 15A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
15 A
Through Hole
PC Pin
-
AS
20kHz ~ 200kHz
Non-Invasive (Solid Core)
-
700VµS
-
4.5Ohm Secondary
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-103
CURR SENSE XFMR 1:300 T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
PC Pin
-
AS
20kHz ~ 200kHz
Non-Invasive (Solid Core)
250 mH
900VµS
-
10Ohm Max
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-111
CURR SENSE XFMR 1:100CT 15A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
PC Pin
-
AS
20kHz ~ 200kHz
Non-Invasive (Solid Core)
25 mH
350VµS
-
550mOhm Max
0.677" L x 0.375" W (17.20mm x 9.53mm)
0.803" (20.40mm)
AS-400
XFRMR CURR 1A 1:100 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.701" L x 0.504" W (17.80mm x 12.80mm)
0.787" (20.00mm)
AS-401
XFRMR CURR 2A 1:100 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.906" L x 0.610" W (23.00mm x 15.50mm)
0.984" (25.00mm)
AS-405
XFRMR CURR 50A 1:500 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.906" L x 0.610" W (23.00mm x 15.50mm)
0.984" (25.00mm)
AS-200
XFRMR CURR 15A 1:50 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.571" L x 0.772" W (14.50mm x 19.60mm)
0.709" (18.00mm)
AS-201
XFRMR CURR 15A 1:100 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.571" L x 0.772" W (14.50mm x 19.60mm)
0.709" (18.00mm)
AS-202
XFRMR CURR 15A 1:200 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.571" L x 0.772" W (14.50mm x 19.60mm)
0.709" (18.00mm)
AS-300
XFRMR CURR 15A 1:50 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.701" L x 0.902" W (17.80mm x 22.90mm)
0.701" (17.80mm)
AS-301
XFRMR CURR 15A 1:100 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.701" L x 0.902" W (17.80mm x 22.90mm)
0.701" (17.80mm)
AS-302
XFRMR CURR 15A 1:200 VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.701" L x 0.902" W (17.80mm x 22.90mm)
0.701" (17.80mm)
AS-210
XFRMR CURR 15A 1:50CT VRT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
AS
-
-
-
-
-
-
0.571" L x 0.772" W (14.50mm x 19.60mm)
0.709" (18.00mm)

About  Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.