K, Hartman Series, Contactors (Electromechanical)

Results:
12
Manufacturer
Series
Contact Rating (Current)
Must Release Voltage
Termination Style
Features
Operating Temperature
Must Operate Voltage
Contact Form
Switching Voltage
Coil Voltage
Mounting Type
Results remaining12
Applied Filters:
K, Hartman
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTermination StyleOperating TemperatureContact FormContact Rating (Current)Switching VoltageMust Operate VoltageMust Release VoltageSeriesCoil VoltageFeatures
8-1616977-1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Connector
-55°C ~ 85°C
SPST-NC (DB) (1 Form Y)
200 A
28VDC - Nom
18 VDC
1 VDC
K, Hartman
28 ~ 32VDC
Auxiliary Contacts, Sealed - Fully
K500B4B01
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Connector
-55°C ~ 85°C
SPST-NC (DB) (1 Form Y)
500 A
28VDC - Nom
18 VDC
10 VDC
K, Hartman
28VDC
Auxiliary Contacts, Sealed - Fully
K300A5C6
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Connector
-55°C ~ 85°C
SPST-NC (DB) (1 Form Y)
300 A
28VDC - Nom
16 VDC
9 VDC
K, Hartman
28 ~ 32VDC
Auxiliary Contacts, Sealed - Fully
K1000A1F03
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Stud
-51°C ~ 71°C
SPST-NO (DM) (1 Form X)
1000 A
28VDC - Nom
18 VDC
8 VDC
K, Hartman
28VDC
Sealed - Fully
K200A1C
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
-55°C ~ 85°C
SPST-NO (DM) (1 Form X)
200 A
28VDC - Nom
18 VDC
9 VDC
K, Hartman
28VDC
Sealed - Fully
K500A7C01
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Bolt Down, Connector
-55°C ~ 85°C
SPST-NO (DM) (1 Form X)
500 A
28VDC - Nom
18 VDC
7 VDC
K, Hartman
28VDC
Auxiliary Contacts
K4001A3C
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Connector, Stud
-55°C ~ 85°C
SPST-NO (DM) (1 Form X)
400 A
28VDC - Nom
13 VDC
9 VDC
K, Hartman
28VDC
Auxiliary Contacts
1-1616520-0
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Stud
-55°C ~ 125°C
3PST-NO (3 Form A)
50 A
115VAC, 28VDC - Max
18 VDC
1.5 VDC
K, Hartman
28VDC
Auxiliary Contacts, Sealed - Hermetically
K400B1F
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
-55°C ~ 85°C
SPST-NO (DM) (1 Form X)
400 A
28VDC - Nom
18 VDC
7 VDC
K, Hartman
28VDC
Sealed - Fully
K400A1F
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
-55°C ~ 85°C
SPST-NO (DM) (1 Form X)
400 A
28VDC - Nom
18 VDC
7 VDC
K, Hartman
28VDC
Sealed - Fully
K200A1C1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
-55°C ~ 85°C
SPST-NC (DB) (1 Form Y)
200 A
28VDC - Nom
18 VDC
1 VDC
K, Hartman
28VDC
Sealed - Fully
K4001B5C2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Bolt Down, Connector
-55°C ~ 85°C
SPST-NO (DM) (1 Form X)
400 A
28VDC - Nom
13 VDC
9 VDC
K, Hartman
28VDC
Auxiliary Contacts

About  Contactors (Electromechanical)

Electromechanical contactors are devices that enable the control of large electrical loads by utilizing a smaller control signal. These contactors act as switches, allowing for the convenient and efficient activation or deactivation of heavy-duty electrical equipment. Contactors are available in a range of contact ratings, which determine their capacity to handle specific load sizes. The ratings typically include values such as 6A, 8A, 9A, 10A, 12A, 14A, 15A, 18A, 20A, 22A, 24A, 25A, 26A, 30A, 32A, 35A, 40A, 50A, 60A, 62A, 65A, 70A, 74A, 75A, 80A, 85A, 90A, 100A, 110A, 120A, 130A, 135A, 150A, 160A, 176A, 185A, 200A, 225A, 250A, 265A, 300A, 330A, 350A, 400A, 500A, 600A, or 1000A. These contact ratings indicate the maximum current that the contactor can handle without experiencing performance issues or damage. Choosing the appropriate contactor with a suitable rating is crucial to ensure safe and reliable operation of electrical systems and equipment. With their ability to control high-power loads, electromechanical contactors find extensive application in various industries where the operation of heavy machinery, motors, lighting systems, and other power-consuming devices is involved. They play a vital role in managing electrical power distribution, enabling efficient control and protection of electrical circuits.