280 Series, Contactors (Electromechanical)

Results:
17
Manufacturer
Series
Must Operate Voltage
Contact Rating (Current)
Coil Voltage
Must Release Voltage
Contact Form
Operating Temperature
Switching Voltage
Termination Style
Features
Mounting Type
Results remaining17
Applied Filters:
280
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeContact FormOperating TemperatureSeriesTermination StyleCoil VoltageContact Rating (Current)Switching VoltageMust Operate VoltageMust Release VoltageFeatures
280-D20N2XAD
2 Pole, 20A, 120V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
DPST-NO (2 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
120VAC
20 A
277VAC - Max
88 VAC
20 VAC
Insulation - Class B
280-D30N1NXC
1 Pole, 30A, 24V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
SPST-NO (1 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
24VAC
30 A
277VAC - Max
18VAC
6 VAC
Insulation - Class B
280-D30N2XC
2 Pole, 30A, 24V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
DPST-NO (2 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
24VAC
30 A
277VAC - Max
18 VAC
6 VAC
Insulation - Class B
280-D40N2XC
2 Pole, 40A, 24V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
DPST-NO (2 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
24VAC
40 A
277VAC - Max
18 VAC
6 VAC
Insulation - Class B
280-D30N3XAD
3 Pole, 30A, 120V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
120VAC
30 A
277VAC - Max
88 VAC
20 VAC
Insulation - Class B
280-D30N3XC
3 Pole, 30A, 24V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
24VAC
30 A
277VAC - Max
18 VAC
6 VAC
Insulation - Class B
280-D40N3XAD
3 Pole, 40A, 120V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
120VAC
40 A
277VAC - Max
88 VAC
20 VAC
Insulation - Class B
280-D50N3XE
3 Pole, 50A, 208-240V AC (50/60
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
208 ~ 240VAC
50 A
277VAC - Max
177 VAC
40 VAC
Insulation - Class B
280-D50N3XAD
3 Pole, 50A, 120V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
120VAC
50 A
277VAC - Max
93 VAC
20 VAC
Insulation - Class B
280-D20N2XC
2 Pole, 20A, 24V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
DPST-NO (2 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
24VAC
20 A
277VAC - Max
18 VAC
6 VAC
Insulation - Class B
280-D20N3XAD
3 Pole, 20A, 120V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
120VAC
20 A
277VAC - Max
88 VAC
20 VAC
Insulation - Class B
280-D30N2XAD
2 Pole, 30A, 120V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
DPST-NO (2 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
120VAC
30 A
277VAC - Max
88 VAC
20 VAC
Insulation - Class B
280-D40N2XAD
2 Pole, 40A, 120V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
DPST-NO (2 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
120VAC
40 A
277VAC - Max
88 VAC
20 VAC
Insulation - Class B
280-D30N3XE
3 Pole, 30A, 208-240V AC (50/60
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
208 ~ 240VAC
30 A
277VAC - Max
177 VAC
40 VAC
Insulation - Class B
280-D40N3XE
3 Pole, 40A, 208-240V AC (50/60
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
208 ~ 240VAC
40 A
277VAC - Max
177 VAC
40 VAC
Insulation - Class B
280-D40N3XC
3 Pole, 40A, 24V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
24VAC
40 A
277VAC - Max
18 VAC
6 VAC
Insulation - Class B
280-D50N3XC
3 Pole, 50A, 24V AC (50/60 Hz)
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
3PST-NO (3 Form A)
-40°C ~ 65°C
280
Screw Terminal, Quick Connect - 0.250" (6.3mm)
24VAC
50 A
277VAC - Max
18 VAC
6 VAC
Insulation - Class B

About  Contactors (Electromechanical)

Electromechanical contactors are devices that enable the control of large electrical loads by utilizing a smaller control signal. These contactors act as switches, allowing for the convenient and efficient activation or deactivation of heavy-duty electrical equipment. Contactors are available in a range of contact ratings, which determine their capacity to handle specific load sizes. The ratings typically include values such as 6A, 8A, 9A, 10A, 12A, 14A, 15A, 18A, 20A, 22A, 24A, 25A, 26A, 30A, 32A, 35A, 40A, 50A, 60A, 62A, 65A, 70A, 74A, 75A, 80A, 85A, 90A, 100A, 110A, 120A, 130A, 135A, 150A, 160A, 176A, 185A, 200A, 225A, 250A, 265A, 300A, 330A, 350A, 400A, 500A, 600A, or 1000A. These contact ratings indicate the maximum current that the contactor can handle without experiencing performance issues or damage. Choosing the appropriate contactor with a suitable rating is crucial to ensure safe and reliable operation of electrical systems and equipment. With their ability to control high-power loads, electromechanical contactors find extensive application in various industries where the operation of heavy machinery, motors, lighting systems, and other power-consuming devices is involved. They play a vital role in managing electrical power distribution, enabling efficient control and protection of electrical circuits.