MCB 489 Series, Circuit Breakers

Results:
132
Manufacturer
Series
Current Rating (Amps)
Voltage Rating - AC
Voltage Rating - DC
Number of Poles
Illumination Voltage (Nominal)
Actuator Type
Approval Agency
Illumination
Breaker Type
Mounting Type
Results remaining132
Applied Filters:
MCB 489
Select
ImageProduct DetailPriceAvailabilityECAD ModelVoltage Rating - DCMounting TypeCurrent Rating (Amps)Number of PolesIllumination Voltage (Nominal)Voltage Rating - ACBreaker TypeActuator TypeIlluminationApproval AgencySeries
2479180000
CB MCB 489 3P D 16A ACDC
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
DIN Rail
16A
3
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2479120000
CB MCB 489 3P D 7A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
7A
3
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478530000
CB MCB 489 3P C 63A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
63A
3
-
240 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478490000
CB MCB 489 3P C 35A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
35A
3
-
240 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2479160000
CB MCB 489 3P D 13A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
13A
3
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478500000
CB MCB 489 3P C 40A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
40A
3
-
240 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478480000
CB MCB 489 3P C 32A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
32A
3
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478900000
CB MCB 489 2P D 12A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
125 V
DIN Rail
12A
2
-
480 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478880000
CB MCB 489 2P D 8A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
125 V
DIN Rail
8A
2
-
480 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478240000
CB MCB 489 2P C 35A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
125 V
DIN Rail
35A
2
-
240 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478540000
CB MCB 489 1P D 1A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
60 V
DIN Rail
1A
1
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478590000
CB MCB 489 1P D 3A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
60 V
DIN Rail
3A
1
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478110000
CB MCB 489 2P C 5A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
125 V
DIN Rail
5A
2
-
480 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478950000
CB MCB 489 2P D 25A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
125 V
DIN Rail
25A
2
-
480 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2477920000
CB MCB 489 1P C 13A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
60 V
DIN Rail
13A
1
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478830000
CB MCB 489 2P D 2A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
125 V
DIN Rail
2A
2
-
480 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478600000
CB MCB 489 1P D 4A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
60 V
DIN Rail
4A
1
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478690000
CB MCB 489 1P D 16A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
60 V
DIN Rail
16A
1
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478670000
CB MCB 489 1P D 13A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
60 V
DIN Rail
13A
1
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489
2478730000
CB MCB 489 1P D 32A ACDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
60 V
DIN Rail
32A
1
-
277 V
Thermal Magnetic
Lever
None
CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE
MCB 489

About  Circuit Breakers

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. It serves as a crucial safety device in electrical systems by interrupting the flow of current when a fault occurs. When an abnormal current condition such as an overload or short circuit occurs, the circuit breaker detects it through a built-in sensing mechanism. This mechanism is typically based on magnetic or thermal principles. The sensing element monitors the current passing through the circuit and triggers the circuit breaker to trip when it exceeds a predetermined threshold. Upon detecting a fault, the circuit breaker swiftly interrupts the flow of electricity by opening its contacts. This action effectively isolates the faulty section of the circuit, preventing further damage to the system or potential hazards like fires or electrocution. By cutting off the current flow, the circuit breaker protects sensitive equipment and wiring from excessive heat and prevents the risk of electrical fires. One of the significant advantages of a circuit breaker over a fuse is its ability to be reset. After a fault has been resolved, the circuit breaker can be manually or automatically reset to restore normal operation. This feature eliminates the need for replacement, as is the case with fuses that must be replaced after they operate. It saves time and cost associated with replacing fuses, making circuit breakers a more convenient and economical choice. In addition to their protective function, circuit breakers also provide selective coordination in complex electrical systems. They are designed with various ratings, including current rating, voltage rating, and fault-breaking capacity, to suit different applications and ensure optimal performance. Overall, circuit breakers are indispensable components in electrical systems, safeguarding against overloads and short circuits while offering the flexibility of resetting for uninterrupted operation. Their ability to protect valuable equipment and prevent electrical hazards makes them an essential part of modern electrical infrastructure.