3VA6 Series, Circuit Breakers

Results:
244
Manufacturer
Series
Current Rating (Amps)
Approval Agency
Illumination Voltage (Nominal)
Voltage Rating - DC
Actuator Type
Voltage Rating - AC
Illumination
Number of Poles
Mounting Type
Breaker Type
Results remaining244
Applied Filters:
3VA6
Select
ImageProduct DetailPriceAvailabilityECAD ModelVoltage Rating - DCMounting TypeApproval AgencyCurrent Rating (Amps)Number of PolesIllumination Voltage (Nominal)Voltage Rating - ACBreaker TypeActuator TypeIlluminationSeries
3VA62105KQ322AA0
BRKR 3VA62 3P 100A 35KA ETU8LSIG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62255KP362AA0
BRKR 3VA62 3P 250A 35KA ETU8-LSI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62105KM362AA0
BRKR 3VA62 3P 100A 35KA ETU8-LIG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA63255JP322AA0
BRKR 3VA63 3P 250A 35KA ETU5-LSI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CCC, CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62105KQ362AA0
BRKR 3VA62 3P 100A 35KA ETU8-LSI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62105KT362AA0
BRKR 3VA62 3P 100A 35KA ETU8-LSI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62255KL362AA0
BRKR 3VA62 3P 250A 35KA ETU8-LI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62255KM322AA0
BRKR 3VA62 3P 250A 35KA ETU8-LIG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62105KM322AA0
BRKR 3VA62 3P 100A 35KA ETU8-LIG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62105KT322AA0
BRKR 3VA62 3P 100A 35KA ETU8LSIA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62255HL360AA0
BRKR 3VA62 3P 250A 35KA ETU3-LI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62255KT322AA0
BRKR 3VA62 3P 250A 35KA ETU8LSIA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62255KQ322AA0
BRKR 3VA62 3P 250A 35KA ETU8LSIG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62105JQ362AA0
BRKR 3VA62 3P 100A 35KA ETU5-LSI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62105JT362AA0
BRKR 3VA62 3P 100A 35KA ETU5-LSI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62105JT322AA0
BRKR 3VA62 3P 100A 35KA ETU5LSIA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62105JQ322AA0
BRKR 3VA62 3P 100A 35KA ETU5LSIG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6
3VA62255JT322AA0
BRKR 3VA62 3P 250A 35KA ETU5LSIA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62255JQ322AA0
BRKR 3VA62 3P 250A 35KA ETU5LSIG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
250A
3
-
690 V
-
Lever
None
3VA6
3VA62105KP362AA0
BRKR 3VA62 3P 100A 35KA ETU8-LSI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, CSA, UL
100A
3
-
690 V
-
Lever
None
3VA6

Circuit Breakers

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. It serves as a crucial safety device in electrical systems by interrupting the flow of current when a fault occurs. When an abnormal current condition such as an overload or short circuit occurs, the circuit breaker detects it through a built-in sensing mechanism. This mechanism is typically based on magnetic or thermal principles. The sensing element monitors the current passing through the circuit and triggers the circuit breaker to trip when it exceeds a predetermined threshold. Upon detecting a fault, the circuit breaker swiftly interrupts the flow of electricity by opening its contacts. This action effectively isolates the faulty section of the circuit, preventing further damage to the system or potential hazards like fires or electrocution. By cutting off the current flow, the circuit breaker protects sensitive equipment and wiring from excessive heat and prevents the risk of electrical fires. One of the significant advantages of a circuit breaker over a fuse is its ability to be reset. After a fault has been resolved, the circuit breaker can be manually or automatically reset to restore normal operation. This feature eliminates the need for replacement, as is the case with fuses that must be replaced after they operate. It saves time and cost associated with replacing fuses, making circuit breakers a more convenient and economical choice. In addition to their protective function, circuit breakers also provide selective coordination in complex electrical systems. They are designed with various ratings, including current rating, voltage rating, and fault-breaking capacity, to suit different applications and ensure optimal performance. Overall, circuit breakers are indispensable components in electrical systems, safeguarding against overloads and short circuits while offering the flexibility of resetting for uninterrupted operation. Their ability to protect valuable equipment and prevent electrical hazards makes them an essential part of modern electrical infrastructure.