JAM Series, Circuit Breakers

Results:
16
Manufacturer
Series
Number of Poles
Current Rating (Amps)
Voltage Rating - AC
Illumination Voltage (Nominal)
Voltage Rating - DC
Actuator Type
Approval Agency
Illumination
Mounting Type
Breaker Type
Results remaining16
Applied Filters:
JAM
Select
ImageProduct DetailPriceAvailabilityECAD ModelCurrent Rating (Amps)Voltage Rating - ACVoltage Rating - DCMounting TypeApproval AgencyIlluminationNumber of PolesIllumination Voltage (Nominal)SeriesBreaker TypeActuator Type
JAM-1-1RLS5R-30256-173
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
1
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAMP-3-1RLS4R-30273-271
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
3
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAMPM6-2RLS4-30717-1
CIR BRKR MAG-HYDR LEVER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
6
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-3-1REC4-63-5-B4-200
CIR BRKR MAG-HYDR 200A 240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
200A
240 V
-
Panel Mount
-
-
3
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-3-1REC5-63-5-B4-200
CIR BRKR MAG-HYDR 200A 240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
200A
240 V
-
Panel Mount
-
-
3
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-1-1RLS5R-30256-231
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
1
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-1-1RLS5R-30256-211
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
1
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-1-1RLS5R-30256-221
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
1
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-1-1RLS5R-30256-238
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
1
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAMP-2-1RLS4R-30269-251
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
2
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAMP-4-1RLS4-30285-1
CIR BRKR MAG-HYDR LEVER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
4
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-3-1REC4-63-5-B4-250
CIR BRKR MAG-HYDR 250A 240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
250A
240 V
-
Panel Mount
-
-
3
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-1-1RLS5R-30256-196
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
1
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAM-1-1RLS5R-30256-199
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
1
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAMP-3-1RLS4R-30273-281
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
3
-
JAM
Magnetic (Hydraulic Delay)
Lever
JAMP-2-1RLS4R-30269-261
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Panel Mount
-
-
2
-
JAM
Magnetic (Hydraulic Delay)
Lever

About  Circuit Breakers

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. It serves as a crucial safety device in electrical systems by interrupting the flow of current when a fault occurs. When an abnormal current condition such as an overload or short circuit occurs, the circuit breaker detects it through a built-in sensing mechanism. This mechanism is typically based on magnetic or thermal principles. The sensing element monitors the current passing through the circuit and triggers the circuit breaker to trip when it exceeds a predetermined threshold. Upon detecting a fault, the circuit breaker swiftly interrupts the flow of electricity by opening its contacts. This action effectively isolates the faulty section of the circuit, preventing further damage to the system or potential hazards like fires or electrocution. By cutting off the current flow, the circuit breaker protects sensitive equipment and wiring from excessive heat and prevents the risk of electrical fires. One of the significant advantages of a circuit breaker over a fuse is its ability to be reset. After a fault has been resolved, the circuit breaker can be manually or automatically reset to restore normal operation. This feature eliminates the need for replacement, as is the case with fuses that must be replaced after they operate. It saves time and cost associated with replacing fuses, making circuit breakers a more convenient and economical choice. In addition to their protective function, circuit breakers also provide selective coordination in complex electrical systems. They are designed with various ratings, including current rating, voltage rating, and fault-breaking capacity, to suit different applications and ensure optimal performance. Overall, circuit breakers are indispensable components in electrical systems, safeguarding against overloads and short circuits while offering the flexibility of resetting for uninterrupted operation. Their ability to protect valuable equipment and prevent electrical hazards makes them an essential part of modern electrical infrastructure.