GFR Series, Circuit Breakers

Results:
264
Manufacturer
Series
Current Rating (Amps)
Number of Poles
Voltage Rating - DC
Voltage Rating - AC
Approval Agency
Breaker Type
Illumination Voltage (Nominal)
Actuator Type
Illumination
Mounting Type
Results remaining264
Applied Filters:
GFR
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApproval AgencyCurrent Rating (Amps)Illumination Voltage (Nominal)Number of PolesVoltage Rating - ACSeriesBreaker TypeActuator TypeIlluminationVoltage Rating - DC
GFR4C32300
EGFP+OL 32A480Y277V AC 300MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
32A
-
3
277 V
GFR
-
Lever
None
-
GFR2D25030
EGFP+OL 25A277V AC 30MA D TRIP 1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
cULus, UL1077
25A
-
1
277 V
GFR
Ground Fault
Lever
None
-
GFR2C25030
EGFP+OL 25A277V AC 30MA C TRIP 1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
25A
-
1
277 V
GFR
-
Lever
None
-
GFR2B25030
EGFP+OL 25A277V AC 30MA B TRIP 1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
25A
-
1
277 V
GFR
-
Lever
None
-
GFR4D08300
EGFP+OL 8A480Y277V AC 300MA D TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
8A
-
3
277 V
GFR
-
Lever
None
-
GFR4D08030
EGFP+OL 8A480Y277V AC 30MA D TRI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
8A
-
3
277 V
GFR
-
Lever
None
-
GFR4D06300
EGFP+OL 6A480Y277V AC 300MA D TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
6A
-
3
277 V
GFR
-
Lever
None
-
GFR4D06030
EGFP+OL 6A480Y277V AC 30MA D TRI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
6A
-
3
277 V
GFR
-
Lever
None
-
GFR4C40300
EGFP+OL 40A480Y277V AC 300MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
40A
-
3
277 V
GFR
-
Lever
None
-
GFR4C40100
EGFP+OL 40A480Y277V AC 100MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
40A
-
3
277 V
GFR
-
Lever
None
-
GFR4C30100
EGFP+OL 30A480Y277V AC 100MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
cULus, UL1077
30A
-
3
480 V
GFR
Ground Fault
Lever
None
-
GFR4C32100
EGFP+OL 32A480Y277V AC 100MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
32A
-
3
277 V
GFR
-
Lever
None
-
GFR4C25300
EGFP+OL 25A480Y277V AC 300MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
25A
-
3
277 V
GFR
-
Lever
None
-
GFR4C20300
EGFP+OL 20A480Y277V AC 300MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
20A
-
3
277 V
GFR
-
Lever
None
-
GFR4C15100
EGFP+OL 15A480Y277V AC 100MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
cULus, UL1077
15A
-
3
480 V
GFR
Ground Fault
Lever
None
-
GFR4C10300
EGFP+OL 10A480Y277V AC 300MA C T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
10A
-
3
277 V
GFR
-
Lever
None
-
GFR4C06030
EGFP+OL 6A480Y277V AC 30MA C TRI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
6A
-
3
277 V
GFR
-
Lever
None
-
GFR4C05300
EGFP+OL 5A480Y277V AC 300MA C TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
5A
-
3
277 V
GFR
-
Lever
None
-
GFR4B40300
EGFP+OL 40A480Y277V AC 300MA B T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
40A
-
3
277 V
GFR
-
Lever
None
-
GFR2C30030
EGFP+OL 30A277V AC 30MA C TRIP 1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-
30A
-
1
277 V
GFR
-
Lever
None
-

Circuit Breakers

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. It serves as a crucial safety device in electrical systems by interrupting the flow of current when a fault occurs. When an abnormal current condition such as an overload or short circuit occurs, the circuit breaker detects it through a built-in sensing mechanism. This mechanism is typically based on magnetic or thermal principles. The sensing element monitors the current passing through the circuit and triggers the circuit breaker to trip when it exceeds a predetermined threshold. Upon detecting a fault, the circuit breaker swiftly interrupts the flow of electricity by opening its contacts. This action effectively isolates the faulty section of the circuit, preventing further damage to the system or potential hazards like fires or electrocution. By cutting off the current flow, the circuit breaker protects sensitive equipment and wiring from excessive heat and prevents the risk of electrical fires. One of the significant advantages of a circuit breaker over a fuse is its ability to be reset. After a fault has been resolved, the circuit breaker can be manually or automatically reset to restore normal operation. This feature eliminates the need for replacement, as is the case with fuses that must be replaced after they operate. It saves time and cost associated with replacing fuses, making circuit breakers a more convenient and economical choice. In addition to their protective function, circuit breakers also provide selective coordination in complex electrical systems. They are designed with various ratings, including current rating, voltage rating, and fault-breaking capacity, to suit different applications and ensure optimal performance. Overall, circuit breakers are indispensable components in electrical systems, safeguarding against overloads and short circuits while offering the flexibility of resetting for uninterrupted operation. Their ability to protect valuable equipment and prevent electrical hazards makes them an essential part of modern electrical infrastructure.