8345 Series, Circuit Breakers

Results:
391
Manufacturer
Series
Current Rating (Amps)
Number of Poles
Voltage Rating - AC
Actuator Type
Approval Agency
Voltage Rating - DC
Illumination
Mounting Type
Illumination Voltage (Nominal)
Breaker Type
Results remaining391
Applied Filters:
8345
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeCurrent Rating (Amps)IlluminationIllumination Voltage (Nominal)Number of PolesVoltage Rating - DCSeriesBreaker TypeActuator TypeApproval AgencyVoltage Rating - AC
8345-B23B-T9M0-DB1B1B-30A
CIR BRKR MAG-HYDR 30A 80VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
30A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
-
8345-F22B-S3M0-DB1B4B-0,4A-V
CIRCUIT BREAKER HYDRAULIC MAGN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
400mA
None
-
2
80 V
8345
Magnetic (Hydraulic Delay)
Lever
-
480 V
8345-B02A-S3M0-DB2B2C-15A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
15A
-
-
2
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B02B-T3M1-DB1B1B-50A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
50A
-
-
2
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B03A-T3T2-DB2B1C-40A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
40A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-E03B-S3T2-DB1B1C-X8345-S02HW102M-20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B01A-T3M1-DB1B1B-25A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
25A
-
-
1
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B22B-T9M0-DB1B1B-30A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
30A
-
-
2
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-SR0007-20A
CIR BRKR THRM 20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
-
-
1
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B22A-T3T2-DB1B1B-20A
CIRCUIT BREAKER HYDRAULIC MAGN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
None
-
2
80 V
8345
Magnetic (Hydraulic Delay)
Lever
-
480 V
8345-B01A-T3M2-DB1B1B-30A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
30A
-
-
1
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B01A-T3M2-DB1B1B-6A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
6A
-
-
1
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B03A-T3M1-DB1B1B-50A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
50A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B24A-T3K2-DB1B2B-16A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
16A
-
-
4
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-E03B-S3M2-DB1B1C-X8345-S02HW102M-10A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B01A-T3M1-DB1B1B-20A-V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
-
-
1
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
277 V
8345-B23A-T3M0-DB1B1B-30A
CR BKR MAG-HYDR 30A 480VAC/80VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
30A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
480 V
8345-C03A-V3T2-DB2A1C-60A
CR BKR MAG-HYDR 60A 480VAC/80VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
60A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
480 V
8345-C12A-S3M2-DB1B1C-15A
CR BKR MAG-HYDR 15A 480VAC/80VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
15A
-
-
2
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
480 V
8345-C23A-U3M2-DB1A1B-20A
CR BKR MAG-HYDR 20A 480VAC/80VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
-
-
3
80 V
8345
Magnetic (Hydraulic Delay)
Lever
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
480 V

About  Circuit Breakers

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. It serves as a crucial safety device in electrical systems by interrupting the flow of current when a fault occurs. When an abnormal current condition such as an overload or short circuit occurs, the circuit breaker detects it through a built-in sensing mechanism. This mechanism is typically based on magnetic or thermal principles. The sensing element monitors the current passing through the circuit and triggers the circuit breaker to trip when it exceeds a predetermined threshold. Upon detecting a fault, the circuit breaker swiftly interrupts the flow of electricity by opening its contacts. This action effectively isolates the faulty section of the circuit, preventing further damage to the system or potential hazards like fires or electrocution. By cutting off the current flow, the circuit breaker protects sensitive equipment and wiring from excessive heat and prevents the risk of electrical fires. One of the significant advantages of a circuit breaker over a fuse is its ability to be reset. After a fault has been resolved, the circuit breaker can be manually or automatically reset to restore normal operation. This feature eliminates the need for replacement, as is the case with fuses that must be replaced after they operate. It saves time and cost associated with replacing fuses, making circuit breakers a more convenient and economical choice. In addition to their protective function, circuit breakers also provide selective coordination in complex electrical systems. They are designed with various ratings, including current rating, voltage rating, and fault-breaking capacity, to suit different applications and ensure optimal performance. Overall, circuit breakers are indispensable components in electrical systems, safeguarding against overloads and short circuits while offering the flexibility of resetting for uninterrupted operation. Their ability to protect valuable equipment and prevent electrical hazards makes them an essential part of modern electrical infrastructure.