3130-F Series, Circuit Breakers

Results:
137
Manufacturer
Series
Current Rating (Amps)
Illumination Voltage (Nominal)
Illumination
Number of Poles
Approval Agency
Voltage Rating - DC
Actuator Type
Voltage Rating - AC
Breaker Type
Mounting Type
Results remaining137
Applied Filters:
3130-F
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeCurrent Rating (Amps)Voltage Rating - ACNumber of PolesActuator TypeVoltage Rating - DCSeriesBreaker TypeIlluminationIllumination Voltage (Nominal)Approval Agency
3130-F110-P7T1-W19QY7-0.5A
CIR BRKR THRM 500MA 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
500mA
250 V
1
Rocker
50 V
3130-F
Thermal
Green
185V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W02Q-8S0018-16A
CIR BRKR THRM 16A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
16A
250 V
1
Rocker
50 V
3130-F
Thermal
None
-
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W14QR2-8A
CIR BRKR THRM 8A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
8A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
10 ~ 14V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W19QY2-10A
CIR BRKR THRM 10A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
10 ~ 14V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F311-P7T1-W12QY3-10A
CIR BRKR THRM 10A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
20 ~ 28V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F311-P7T1-W14QR6-5A
CIR BRKR THRM 5A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
5A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
90 ~ 140V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W14QR2-4A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
4A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
10 ~ 14V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W19QY6-6A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
6A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
90 ~ 140V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W14QR2-10A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
10 ~ 14V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W19QY6-10A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
90 ~ 140V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QR3-10A
CIR BRKR THRM 10A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
20 ~ 28V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QR3-15A
CIR BRKR THRM 15A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
15A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
20 ~ 28V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QR3-6A
CIR BRKR THRM 6A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
6A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
20 ~ 28V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QR3-20A
CIR BRKR THRM 20A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
20 ~ 28V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QY6-10A
CIR BRKR THRM 10A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
90 ~ 140V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QY6-15A
CIR BRKR THRM 15A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
15A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
90 ~ 140V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QY6-20A
CIR BRKR THRM 20A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
90 ~ 140V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QY7-10A
CIR BRKR THRM 10A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
10A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
185 ~ 275V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W12QY7-20A
CIR BRKR THRM 20A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
20A
250 V
1
Rocker
50 V
3130-F
Thermal
Yellow
185 ~ 275V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
3130-F110-P7T1-W14QR2-5A
CIR BRKR THRM 5A 250VAC 50VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
5A
250 V
1
Rocker
50 V
3130-F
Thermal
Red
10 ~ 14V
CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077

About  Circuit Breakers

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. It serves as a crucial safety device in electrical systems by interrupting the flow of current when a fault occurs. When an abnormal current condition such as an overload or short circuit occurs, the circuit breaker detects it through a built-in sensing mechanism. This mechanism is typically based on magnetic or thermal principles. The sensing element monitors the current passing through the circuit and triggers the circuit breaker to trip when it exceeds a predetermined threshold. Upon detecting a fault, the circuit breaker swiftly interrupts the flow of electricity by opening its contacts. This action effectively isolates the faulty section of the circuit, preventing further damage to the system or potential hazards like fires or electrocution. By cutting off the current flow, the circuit breaker protects sensitive equipment and wiring from excessive heat and prevents the risk of electrical fires. One of the significant advantages of a circuit breaker over a fuse is its ability to be reset. After a fault has been resolved, the circuit breaker can be manually or automatically reset to restore normal operation. This feature eliminates the need for replacement, as is the case with fuses that must be replaced after they operate. It saves time and cost associated with replacing fuses, making circuit breakers a more convenient and economical choice. In addition to their protective function, circuit breakers also provide selective coordination in complex electrical systems. They are designed with various ratings, including current rating, voltage rating, and fault-breaking capacity, to suit different applications and ensure optimal performance. Overall, circuit breakers are indispensable components in electrical systems, safeguarding against overloads and short circuits while offering the flexibility of resetting for uninterrupted operation. Their ability to protect valuable equipment and prevent electrical hazards makes them an essential part of modern electrical infrastructure.