Balluff

Balluff

Established in 1921 in Neuhausen a. d. F., Germany, Balluff is globally recognized for its innovative technology, commitment to quality, and extensive expertise in industrial automation. A renowned sensor and automation expert, this fourth-generation family-owned company provides a wide range of top-notch sensor, identification, network, and software solutions to meet the diverse needs of various industries.

Sensor, Transducer Amplifiers

Results:
35
Series
Current - Supply
Operating Temperature
Output Type
Voltage - Supply
Mounting Type
Amplifier Type
Results remaining35
Applied Filters:
Balluff
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesMounting TypeVoltage - SupplyOutput TypeCurrent - SupplyAmplifier TypeOperating Temperature
BIC007K
FUNCTION=SIGNAL TRANSMISSION, SI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24VDC
PNP
500 mA
General Purpose
-5°C ~ 65°C
BAE00PT
PHOTOELECTRIC SENSORS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
10V ~ 30V
-
General Purpose
-10°C ~ 50°C
BAE00N4
PHOTOELECTRIC SENSORS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
15V ~ 30V
Analog
-
General Purpose
-10°C ~ 50°C
BAE00N5
PHOTOELECTRIC SENSORS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
15V ~ 30V
Analog
-
General Purpose
-10°C ~ 50°C
BAE00NL
PHOTOELECTRIC SENSORS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
10V ~ 30V
-
General Purpose
-10°C ~ 50°C
BAE002J
FUNCTION=SWITCHING AMPLIFIER UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
10V ~ 30V
10 mA
General Purpose
0°C ~ 60°C
BAE002M
FUNCTION=SWITCHING AMPLIFIER UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
10V ~ 30V
PNP
10 mA
General Purpose
0°C ~ 60°C
BAE002N
FUNCTION=SWITCHING AMPLIFIER UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
10V ~ 30V
NPN
10 mA
General Purpose
0°C ~ 60°C
BIC005A
FUNCTION=UNI IO-LINK, SIGNAL TYP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24V
-
1 A
General Purpose
-5°C ~ 55°C
BIC005C
FUNCTION=UNI IO-LINK, SIGNAL TYP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24VDC
-
500 mA
General Purpose
-5°C ~ 55°C
BAE00NJ
PHOTOELECTRIC SENSORS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SA-OH
DIN Rail
10V ~ 30V
PNP-NO/NC
-
General Purpose
-10°C ~ 50°C
BIC007H
FUNCTION=IO-LINK SIGNAL TRANSMIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24VDC
-
1.7 A
General Purpose
-5°C ~ 55°C
BIC007J
FUNCTION=SIGNAL TRANSMISSION, SI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24V
PNP
1 A
General Purpose
-5°C ~ 65°C
BIC0009
FUNCTION=SIGNAL TRANSMISSION, SI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24V
PNP
1 A
General Purpose
0°C ~ 55°C
BIC0077
FUNCTION=SIGNAL TRANSMISSION, SI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24V
PNP
50 mA
General Purpose
-10°C ~ 50°C
BAE002K
FUNCTION=FREQUENCY MONITOR UP TO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
10V ~ 30V
PNP
10 mA
General Purpose
0°C ~ 60°C
BAE002H
FUNCTION=SWITCHING AMPLIFIER UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
10V ~ 30V
NPN-NO/NC
10 mA
General Purpose
0°C ~ 60°C
BAE00KJ
SENSOR AMPLIFIER DIN RAIL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
15V ~ 30V
Analog
50 mA
General Purpose
-10°C ~ 70°C
BIC0070
FUNCTION=IO-LINK SIGNAL TRANSMIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24V
-
1 A
General Purpose
-5°C ~ 65°C
BIC007F
FUNCTION=IO-LINK SIGNAL TRANSMIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Panel Mount
24V
-
1.9 A
General Purpose
-5°C ~ 55°C

About  Sensor, Transducer Amplifiers

Sensor amplifiers are designed to process raw output signals from sensors and convert them into a usable form by employing application-specific circuitry. This typically involves amplifying the sensor's output and converting it into various types, such as analog voltage or current, digital, NPN or PNP transistor, linear, or relay contact(s). These amplifiers are equipped with specific circuit configurations tailored to the requirements of different sensors, allowing for precise and accurate signal conditioning. By amplifying and converting the sensor output, these devices ensure that the resulting signal is compatible with the input requirements of downstream components or systems. In terms of physical installation, sensor amplifiers are available in various mounting types to accommodate different application needs. These include bracket-mounted, cable-mounted, chassis-mounted, DIN rail-mounted, board surface-mounted, and through-hole-mounted configurations. This diverse range of mounting options enables the seamless integration of sensor amplifiers into a wide array of systems and environments. In summary, sensor amplifiers play a crucial role in converting and conditioning raw sensor output signals into a format suitable for further processing. They achieve this through specialized circuitry that amplifies and converts the signals into various output types. Additionally, the availability of different mounting types ensures versatility and compatibility with diverse installation requirements.