WCAP-ATG5 Series, Aluminum Electrolytic Capacitors

Results:
204
Manufacturer
Series
Ripple Current @ High Frequency
Ripple Current @ Low Frequency
Capacitance
Height - Seated (Max)
Size / Dimension
Lead Spacing
Voltage - Rated
Operating Temperature
Tolerance
Impedance
Polarization
Applications
Surface Mount Land Size
Mounting Type
Lifetime @ Temp.
ESR (Equivalent Series Resistance)
Ratings
Package / Case
Results remaining204
Applied Filters:
WCAP-ATG5
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeToleranceApplicationsPackage / CaseImpedanceRatingsOperating TemperatureCapacitanceHeight - Seated (Max)Lead SpacingLifetime @ Temp.Size / DimensionSurface Mount Land SizeSeriesVoltage - RatedPolarizationRipple Current @ Low FrequencyRipple Current @ High FrequencyESR (Equivalent Series Resistance)
860021373003
1+
$0.3042
5+
$0.2873
10+
$0.2704
Quantity
1,197 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-25°C ~ 105°C
2.2 µF
0.650" (16.50mm)
0.098" (2.50mm)
2000 Hrs @ 105°C
0.248" Dia (6.30mm)
-
WCAP-ATG5
400 V
Polar
34 mA @ 120 Hz
57.8 mA @ 100 kHz
-
860020573008
1+
$0.2028
5+
$0.1915
10+
$0.1803
Quantity
250 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
100 µF
0.492" (12.50mm)
0.098" (2.50mm)
2000 Hrs @ 105°C
0.248" Dia (6.30mm)
-
WCAP-ATG5
35 V
Polar
160 mA @ 120 Hz
244.8 mA @ 100 kHz
-
860020581026
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
4700 µF
1.476" (37.50mm)
0.295" (7.50mm)
2000 Hrs @ 105°C
0.709" Dia (18.00mm)
-
WCAP-ATG5
35 V
Polar
1.9 A @ 120 Hz
2.432 A @ 100 kHz
-
860021380017
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-25°C ~ 105°C
68 µF
1.043" (26.50mm)
0.295" (7.50mm)
2000 Hrs @ 105°C
0.630" Dia (16.00mm)
-
WCAP-ATG5
400 V
Polar
410 mA @ 120 Hz
627.3 mA @ 100 kHz
-
860020680029
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
1800 µF
1.457" (37.00mm)
0.295" (7.50mm)
2000 Hrs @ 105°C
0.630" Dia (16.00mm)
-
WCAP-ATG5
50 V
Polar
1.48 A @ 120 Hz
1.8944 A @ 100 kHz
-
860020580024
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
3300 µF
1.457" (37.00mm)
0.295" (7.50mm)
2000 Hrs @ 105°C
0.630" Dia (16.00mm)
-
WCAP-ATG5
35 V
Polar
1.65 A @ 120 Hz
2.112 A @ 100 kHz
-
860020780025
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
1000 µF
1.299" (33.00mm)
0.295" (7.50mm)
2000 Hrs @ 105°C
0.630" Dia (16.00mm)
-
WCAP-ATG5
63 V
Polar
1.185 A @ 120 Hz
1.6353 A @ 100 kHz
-
860020775016
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
120 µF
0.689" (17.50mm)
0.197" (5.00mm)
2000 Hrs @ 105°C
0.394" Dia (10.00mm)
-
WCAP-ATG5
63 V
Polar
255 mA @ 120 Hz
351.9 mA @ 100 kHz
-
860020781027
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
1500 µF
1.299" (33.00mm)
0.295" (7.50mm)
2000 Hrs @ 105°C
0.709" Dia (18.00mm)
-
WCAP-ATG5
63 V
Polar
1.35 A @ 120 Hz
1.728 A @ 100 kHz
-
860021373005
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-25°C ~ 105°C
3.3 µF
0.650" (16.50mm)
0.098" (2.50mm)
2000 Hrs @ 105°C
0.248" Dia (6.30mm)
-
WCAP-ATG5
400 V
Polar
35 mA @ 120 Hz
59.5 mA @ 100 kHz
-
860021378013
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-25°C ~ 105°C
22 µF
0.846" (21.50mm)
0.197" (5.00mm)
2000 Hrs @ 105°C
0.512" Dia (13.00mm)
-
WCAP-ATG5
400 V
Polar
170 mA @ 120 Hz
260.1 mA @ 100 kHz
-
860020275021
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
2700 µF
1.043" (26.50mm)
0.197" (5.00mm)
2000 Hrs @ 105°C
0.394" Dia (10.00mm)
-
WCAP-ATG5
10 V
Polar
880 mA @ 120 Hz
1.1264 A @ 100 kHz
-
860020778021
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
470 µF
0.846" (21.50mm)
0.197" (5.00mm)
2000 Hrs @ 105°C
0.512" Dia (13.00mm)
-
WCAP-ATG5
63 V
Polar
690 mA @ 120 Hz
952.2 mA @ 100 kHz
-
860020275016
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
1200 µF
0.689" (17.50mm)
0.197" (5.00mm)
2000 Hrs @ 105°C
0.394" Dia (10.00mm)
-
WCAP-ATG5
10 V
Polar
630 mA @ 120 Hz
806.4 mA @ 100 kHz
-
860020672012
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
33 µF
0.492" (12.50mm)
0.079" (2.00mm)
2000 Hrs @ 105°C
0.197" Dia (5.00mm)
-
WCAP-ATG5
50 V
Polar
75 mA @ 120 Hz
114.75 mA @ 100 kHz
-
860020272006
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
120 µF
0.492" (12.50mm)
0.079" (2.00mm)
2000 Hrs @ 105°C
0.197" Dia (5.00mm)
-
WCAP-ATG5
10 V
Polar
110 mA @ 120 Hz
151.8 mA @ 100 kHz
-
860020772007
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
3.3 µF
0.492" (12.50mm)
0.079" (2.00mm)
2000 Hrs @ 105°C
0.197" Dia (5.00mm)
-
WCAP-ATG5
63 V
Polar
28 mA @ 120 Hz
47.6 mA @ 100 kHz
-
860020772001
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
0.1 µF
0.492" (12.50mm)
0.079" (2.00mm)
2000 Hrs @ 105°C
0.197" Dia (5.00mm)
-
WCAP-ATG5
63 V
Polar
1.3 mA @ 120 Hz
2.21 mA @ 100 kHz
-
860020372005
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
68 µF
0.492" (12.50mm)
0.079" (2.00mm)
2000 Hrs @ 105°C
0.197" Dia (5.00mm)
-
WCAP-ATG5
16 V
Polar
105 mA @ 120 Hz
160.65 mA @ 100 kHz
-
860020572001
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
General Purpose
Radial, Can
-
-
-40°C ~ 105°C
4.7 µF
0.492" (12.50mm)
0.079" (2.00mm)
2000 Hrs @ 105°C
0.197" Dia (5.00mm)
-
WCAP-ATG5
35 V
Polar
28 mA @ 120 Hz
47.6 mA @ 100 kHz
-

About  Aluminum Electrolytic Capacitors

Aluminum electrolytic capacitors are a type of polarized capacitor that use an aluminum electrode material with an oxide dielectric. These capacitors have a higher capacitance-voltage (CV) product per unit volume compared to other types of capacitors such as ceramic or film capacitors. They find use in a variety of applications, including power supplies, audio equipment, and industrial electronics. Aluminum electrolytic capacitors consist of two electrodes, an anode (+) made of pure aluminum foil and a cathode (-) made of a conductive liquid electrolyte with a separator in between. The aluminum oxide layer that forms on the anode acts as the dielectric, allowing the capacitor to store charge. The thinner the oxide layer, the greater the capacitance of the capacitor. One advantage of aluminum electrolytic capacitors is their ability to handle high levels of capacitance while maintaining a small form factor. Additionally, they have a low equivalent series resistance (ESR), which allows them to provide stable performance in high frequency circuits. However, there are also limitations to the use of aluminum electrolytic capacitors. They are sensitive to factors such as temperature, voltage, and current, which can cause them to degrade or even fail over time. Additionally, these capacitors are polarized and must be connected with the correct polarity to function properly. In summary, aluminum electrolytic capacitors are a useful type of capacitor that offers high capacitance-voltage product and stable performance in high frequency circuits. While they have advantages, they also have limitations that must be considered in their use.